Single-gap timing RPCs with bidimensional position-sensitive readout for very accurate TOF systems

نویسندگان

  • A. Blanco
  • R. Ferreira-Marques
  • Ch. Finck
  • P. Fonte
  • A. Gobbi
  • A. Policarpo
چکیده

In this work, we report the development and performance of single-gap timing RPCs equipped with a 3mm FWHM resolution bidimensional position-sensitive readout and reaching a timing resolution of 55 ps s at an efficiency of 75% for MIPs. These chambers are aimed to be applied in a multilayer geometry, forming small and very accurate TOF systems. The avalanche localization capability would provide information for accurate flight-path determination and allow the offline correction of any position dependent effects in the chamber, like gap inhomogeneities or edge effects. The multilayer geometry would provide redundant timing information, which, besides improving the timing resolution, can be used for reducing the timing tails and for the self-calibration of the device. From the experimental singlechamber data it can be calculated that a four-layer configuration of such chambers would yield a time resolution of 33 ps s at a 95% efficiency, essentially free of timing tails. r 2003 Elsevier Science B.V. All rights reserved.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

High-resolution TOF with RPCs

In this work, we describe some recent results concerning the application of Resistive Plate Chambers operated in avalanche mode at atmospheric pressure for high-resolution time-of-flight measurements. A combination of multiple, mechanically accurate, thin gas gaps and state-of-the-art electronics yielded an overall (detector plus electronics) timing accuracy better than 50 ps s with a detection...

متن کامل

Performances of multi - gap timing RPCs for relativistic ions in the range Z = 1 - 6

We present the performance of Multi-gap timing RPCs under irradiation by fully stripped relativistic ions (γβ =2.7, Z=1-6). A time resolution of 80 ps at high efficiency has been obtained by just using standard 'off the shelf' 4-gap timing RPCs from the new HADES ToF wall. The resolution worsened to 100 ps for ∼ 1 kHz/cm 2 proton flux and for ∼ 100 Hz/cm 2 Carbon flux. The chambers were operate...

متن کامل

In-Beam Test Results of the Pestov Glass Resistive Plate Counter Prototypes

D. Bartoş1, G. Caragheorgheopol1, F. Dohrmann2, K.D. Hildenbrand3, B. Kaempfer2, R. Kotte2, L. Naumann2, M. Petriş1, M. Petrovici1, V. Simion1, D. Stach2, C. Williams4, and J. Wuestenfeld2 1NIPNE, Bucharest, Romania; 2FZ Dresden Rossendorf, Dresden, Germany; 3GSI, Darmstadt, Germany; 4CERN, Geneva, Switzerland The Compressed Baryonic Matter (CBM) experiment foresees a time-of-flight (TOF) wall ...

متن کامل

A Large-Area Timing RPC

A large-area Resistive Plate Chamber (RPC) with a total active surface of 160×10 cm was built and tested. The surface was segmented into two 5-cm wide strips readout on both ends with customized, very high speed, front-end electronics. A timing resolution σ = 50-75 ps, with an efficiency for Minimum Ionizing Particles (MIPs) larger than 95%, was attained over the whole active area, in addition ...

متن کامل

Design and Construction of a Sensitive Capasitive Sensor System (RESEARCH NOTE)

Design and construction of a capacitor sensor with a precise readout system are described in this paper. A variable air-gap capacitive transducer was constructed and for signalmeasurement a successful attempt was made to exploit the capacitance changes in terms of the phase angle of the detected signal. The reported setup makes it possible to detect capacitance changes of the order of 2.5 fF in...

متن کامل