Colorimetric enzymatic determination of serum total carbon dioxide, as applied to the Vickers Multichannel 300 discrete analyzer.
نویسندگان
چکیده
Phosphoenolpyruvate carbosylase (EC 4.1.1.31) has been used in developing a simple, inexpensive colorimetric assay for serum total carbon dioxide in an open system. The oxaloacetate formed by the action of the enzyme on bicarbonate and phosphoenolpyruvate is measured by use of the diazonium salt of Fast Violet B. Interferences from billirubin, pyruvate, and drugs are negligible. Acetoacetate interference is significant only in highly ketotic samples, and a serum blank corrects for it. Serum protein interference is equivalent to 3.3 plus or minus 1.25 mmol of CO2 per liter and hence is sufficiently constant to be corrected for by use of a serum standard or serum blank. The method has been applied to the Vickers M-300 and D-300 systems and within-batch standard deviations of plus or minus 0.1 to plus or minus 0.6 mmol/liter have been observed. Excellent correlation with orthodox techniques has been obtained.
منابع مشابه
Determination of inorganic phosphorus in serum: Evaluation of three methods applied to the Technicon RA-1000 analyzer
We have evaluated three analytical methods for determining inorganic phosphorus in serum applied to the Technicon RA-I000 analyzer: a fully enzymatic colorimetric method based on the specific system purine nucleoside phosphorylase/xanthine oxidase coupled to an indicator colorimetric reaction similar to the Trinder reaction; a chemical method involving the direct UV measurement of the phosphomo...
متن کاملAutomated measurement of total cholesterol and triglycerides, in "tandem," on the discrete sample analyzer, Gilford System 3500.
We have developed an automated procedure on a discrete sample analyzer, Gilford System 3500, which alternately measures both total serum cholesterol and triglyceride concentrations as a "tandem" procedure. We used Dow Diagnostic's fully enzymatic, colorimetric reagents and aqueous standards to calculate unknowns ratiometrically. Cholesterol and then triglyceride reagent are dispensed into alter...
متن کاملDirect determination of serum chloride with a semiautomated discrete analyzer.
I show how mercuric thiocyanate reagent can be used in assaying serum chloride economically, rapidly, and precisely. I used a semiautomated discrete analyzer with direct concentration read-out capability but the method can easily be applied to many mechanized instruments. Linearity between concentration and color is obtained by adding appropriate amounts of mercuric nitrate to the reagent. As m...
متن کاملA multichannel continuous-flow analyzer.
A 10-channel analyzer is described with which sodium, potassium, chloride, carbon dioxide, calcium, phosphorus, total protein, albumin, albumin blank, and uric acid levels may be determined simultaneously. Operating at the rate of 60 specimens per hour, the instrument uses less than 1 ml. of serum for all 10 determinations. The results appear on 5 two-pen recorders. The report describes the ins...
متن کاملPiccolo® Comprehensive Metabolic Reagent Disc
chemistry analyzer, is intended to be used for the in vitro quantitative determination of alanine aminotransferase (ALT), albumin, alkaline phosphatase (ALP), aspartate aminotransferase (AST), calcium, chloride, creatinine, glucose, potassium, sodium, total bilirubin, total carbon dioxide, total protein, and blood urea nitrogen (BUN) in heparinized whole blood, heparinized plasma, or serum in a...