Comparative study of a responsive insertion technology (RIT) colonoscope versus a variable-stiffness colonoscope.

نویسندگان

  • César Prieto-de-Frías
  • Miguel Muñoz-Navas
  • Cristina Carretero
  • Juan Carrascosa
  • Ma Teresa Betés
  • Susana de-la-Riva
  • Ma Teresa Herraiz
  • José Carlos Súbtil
چکیده

BACKGROUND AND OBJECTIVES recently, Olympus developed a new prototype (XCF-Q180AY2L) with responsive insertion technology (RIT), which besides the still known variable stiffness technology, included a passive bending section and a new high force insertion tube. Our objective was to investigate whether the use of this prototype could ease colonoscope insertion, increasing the cecal intubation rate, and/or shortening the cecal intubation time. MATERIAL AND METHODS the study was designed as a prospective observational study in 305 consecutive patients from a colo-rectal cancer screening program. We compared colonoscopies performed with conventional colonoscopes (CFH180AL/CFQ160L) with those performed with the prototype XCF-Q180AY2L. End points were mean cecal and terminal ileal intubation times, cecum intubation rate, and need for specific maneuvers. All colonoscopies were performedunder sedation with intravenous propofol. Finally, 288 patients were included. RESULTS no complications were observed. Complete cecal intubation rate was 100 % in both groups. The ileum could be reached in 98.95 % of cases. Mean time required to reach the cecum was shorter in the prototype endoscope group (4.31 min, SD 2.63 min) than in the conventional endoscope group (4.66 min, SD 2.52 min) (p < 0.05). Compared with the standard colonoscope group, we observed in the prototype group less subjective sensation of difficultyin the passage of the sigma (p < 0.01), fewer maneuvers when it proved necessary to straighten the scope (p < 0.01), and less frequent need to modify the stiffness of the endoscope (p < 0.05). CONCLUSION we concluded that the prototype endoscope (XCFQ180AY2L) facilitated colonoscope insertion, requiring slightly less time to reach the cecum than a standard colonoscope.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Factors related to the effectiveness of variable stiffness colonoscope: results of a multivariate analysis.

BACKGROUND Various studies and two meta-analysis have shown that a variable stiffness colonoscope improves cecal intubation rate. However, there are few studies on how this colonoscope should be used. OBJECTIVE The aim of this study was to identify factors related to the advancement of the colonoscope when the variable stiffness function is activated. METHODS Prospective study enrolling con...

متن کامل

Use of an electromagnetic colonoscope to assess maneuvers associated with cecal intubation

BACKGROUND Safe and effective colonoscopy is aided by the use of endoscopic techniques and maneuvers (ETM) during the examination including patient repositioning, stiffening of the endoscope and abdominal pressure. AIM To better understand the use and value of ETM during colonoscopy by using a device that allows real-time imaging of the colonoscope insertion shaft. METHODS The use of ETM du...

متن کامل

A new variable stiffness colonoscope makes colonoscopy easier: a randomised controlled trial.

BACKGROUND Colonoscopy remains technically difficult in 10-20% of procedures due to variable colonic anatomy and fixation. The ability to vary endoscope shaft flexibility may help insertion to the caecum. METHODS Consecutive patients attending for day case colonoscopy were randomised to examination with either the conventional Olympus CF200HL (200HL) or a new variable stiffness (VS) colonosco...

متن کامل

Does the variable-stiffness colonoscope makes colonoscopy easier? A meta-analysis of the efficacy of the variable stiffness colonoscope compared with the standard adult colonoscope

BACKGROUND The variable-stiffness colonoscope (VSC) appears to have advantages over the standard adult colonoscope (SAC), although data are conflicting. To provide a comprehensive up-to-date review, we conducted a meta-analysis to compare the efficacies of the VSC and SAC. METHODS Electronic databases, including PubMed, EMBASE, the Cochrane library and the Science Citation Index, were searche...

متن کامل

A linear sigmoid colon passage method in colonoscopy

2 Satoshi Awazu, Risa Araki, Toshihiko Awazu 3 4 Awazu Hospital, Nagasaki, Japan 5 6 Address correspondence to Satoshi Awazu, Awazu Hospital, Nagasaki 851-0251, Japan. Phone: 7 +81-95-826-9088. E-mail: [email protected]. 8 9 10 ABSTRACT 11 12 A previous study revealed loop formation of the colonoscope in the sigmoid colon in 13 79% of patients. Colonoscope looping in the sigmoid colon is ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Revista espanola de enfermedades digestivas : organo oficial de la Sociedad Espanola de Patologia Digestiva

دوره 105 4  شماره 

صفحات  -

تاریخ انتشار 2013