Clinical laboratory evaluation of the Orion SS-20 ionized calcium analyser

نویسندگان

  • Patrick Ferreira
  • Alan M. Bold
چکیده

for the gas stream in the distillation unit. Coagulation of the beer samples, especially when running a large number of samples, can arise in the distillation unit. Coagulation interferes with the smooth flow of sample through the distillation unit and gives erratic results. Coagulation was prevented by mixing the sample with a M potassium hydroxide solution (Figure 2) before pumping it into the distillation unit. The pH of the beer sample then varied between 6 and 7.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparative evaluation of two calcium ion-selective electrode systems, and their utility for monitoring steady-state changes in [Ca2+].

We compared ionized calcium concentrations ([Ca2+]) as measured with two ionized-calcium analyzers: the NOVA 2 and the Orion SS-20. Samples were obtained from 43 human volunteers, 213 patients, and five dogs (106 samples). In the [Ca2+] range of 0.85 to 1.8 mmol/L, [Ca2+] measurements in whole blood with the NOVA 2 consistently exceeded those measured with the Orion SS-20. However, in the norma...

متن کامل

Activity and interference effects in measurement of ionized calcium with ion-selective electrodes.

We assessed the magnitude of the errors in ionized-calcium measurements resulting from changes in electrolyte composition for three different ion-selective electrodes: the Orion Model 93-20, the Radiometer F2112, and the Simon neutral carrier membrane electrode. We attempted to distinguish between errors arising from changes in calcium ion activity and those due to interferences in the electrod...

متن کامل

Evaluation of a new instrument offering sodium, potassium, and ionized calcium in combination with haematocrit, pH and blood gas analysis; the performance of the Nova Stat Profile 1

The Nova Stat Profile 1 analyser, a combined sodium, potassium, ionized calcium, haematocrit and conventional blood gas analyser, was evaluated over a four month period. In addition to assessing and demonstrating that the instrument met analytical requirements, an appreciation of the use of ionised calcium (iCa) was made. Prospective costs were characterised and practical problems of iCa measur...

متن کامل

Effect of pH and NaCl on measurements of ionized calcium in matrices of serum and human albumin with a new calcium-selective electrode.

A neutral ligand ion-exchanger type of ion-selective electrode is used in the current version of the Orion Model SS-20 calcium analyzer. We evaluated it over the pH range 4.0 to 8.5, using albumin solutions containing 150 mmol/L NaCl and pooled patients' serum. Within this pH range response was nernstian, and the relationship between potential (in millivolts) and log [Ca2+] at each pH was linea...

متن کامل

Ion effects in measurement of ionized calcium with a calcium-selective electrode.

We examined the performance characteristics of an improved electrode for measurement of ionized calcium (Orion Research, Inc.) with respect to interferences by Na+, K+, Li+, Mg2+, and H+, as well as the effect of changes in ionic strength and osmolality. At physiologically observed concentrations, all ions except Na+ insignificantly affected ionized-calcium measurements. The decrease in ionized...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of Automatic Chemistry

دوره 1  شماره 

صفحات  -

تاریخ انتشار 1979