[Determination of iodide, thiocyanate and perchlorate ions in environmental water by two-dimensional ion chromatography].

نویسندگان

  • Li Lin
  • Haibo Wang
  • Yali Shi
چکیده

A procedure for the determination of iodide, thiocyanate and perchlorate ions in environmental water by two-dimensional ion chromatography has been developed. At first the iodide, thiocyanate and perchlorate ions were separated from interfering ions by a column (IonPac AS16, 250 mm x 4 mm). The iodide ion, thiocyanate and perchlorate ions were then enriched with an enrichment column (MAC-200, 80 mm x 0.75 mm). In the 2nd-dimensional chromatography, iodide thiocyanate and perchlorate ions were separated and quantified by a capillary column (IonPac AS20 Capillary, 250 mm x 0.4 mm). The linear ranges were 0.05 -100 pg/L with correlation coefficients of 0. 999 9, and the detection limits were 0. 02 - 0.05 micro gg/L. The spiked recoveries of iodide, thiocyanate and perchlorate ions were in the range of 85.1% to 100.1%. The relative standard deviations of the recoveries were 1.7% to 4.9%.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Temporal Patterns in Perchlorate, Thiocyanate, and Iodide Excretion in Human Milk

BACKGROUND Perchlorate and thiocyanate interfere with iodide uptake at the sodium-iodide symporter and are potential disruptors of thyroid hormone synthesis. Perchlorate is a common contaminant of water, food, and human milk. Although it is known that iodide undergoes significant diurnal variations in serum and urinary excretion, less is known about diurnal variations of milk iodide levels. O...

متن کامل

Determination of perchlorate in drinking water by ion chromatography using macrocycle-based concentration and separation methods.

Macrocycle-based ion chromatography provides a convenient, reliable method for the determination of perchlorate ion, which is currently of great interest to the environmental community. This study shows that effective perchlorate determinations can be made using standard conductimetric detection by combining an 18-crown-6-based mobile phase with an underivatized reversed-phase mobile phase ion ...

متن کامل

Perchlorate versus other environmental sodium/iodide symporter inhibitors: potential thyroid-related health effects.

OBJECTIVE Perchlorate is a known competitive inhibitor of the sodium/iodide symporter (NIS). Possible thyroid-related effects of environmental perchlorate have created great health concerns, especially in the US, resulting in a debated reference dose (RfD) of 0.0007 mg/kg per day in drinking water recommended by the National Academy of Sciences (NAS). However, the impact of other environmental ...

متن کامل

Perchlorate, thiocyanate, and nitrate in edible cole crops (Brassica sp.) produced in the lower Colorado River region.

The Colorado River is contaminated with low levels of perchlorate. Perchlorate has the potential to disrupt thyroid function by inhibiting the uptake of iodide. Brassica are rich sources of thiocyanate and nitrate, also inhibitors of iodide uptake. This study was conducted to estimate potential human exposure to perchlorate, thiocyanate, and nitrate from Brassica sp. irrigated with Colorado Riv...

متن کامل

Validation data for the determination of perchlorate in water using ion chromatography with suppressed conductivity detection

BACKGROUND Perchlorate salts are relatively stable, soluble in water, and migrate into groundwater sources. Groundwater is an essential source for drinking water suppliers. Perchlorate bears health risks as it is identified to impair normal thyroid function by interfering with iodine uptake by the thyroid gland. The development of a sensitive analytical method for the determination of perchlora...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Se pu = Chinese journal of chromatography

دوره 31 3  شماره 

صفحات  -

تاریخ انتشار 2013