Asymmetric Mach–Zehnder Interferometer Based Biosensors for Aflatoxin M1 Detection

نویسندگان

  • Tatevik Chalyan
  • Romain Guider
  • Laura Pasquardini
  • Manuela Zanetti
  • Floris Falke
  • Erik Schreuder
  • Rene G. Heideman
  • Cecilia Pederzolli
  • Lorenzo Pavesi
چکیده

In this work, we present a study of Aflatoxin M1 detection by photonic biosensors based on Si₃N₄ Asymmetric Mach-Zehnder Interferometer (aMZI) functionalized with antibodies fragments (Fab'). We measured a best volumetric sensitivity of 10⁴ rad/RIU, leading to a Limit of Detection below 5 × 10(-7) RIU. On sensors functionalized with Fab', we performed specific and non-specific sensing measurements at various toxin concentrations. Reproducibility of the measurements and re-usability of the sensor were also investigated.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Review of Optical Routers in Photonic Networks-on-Chip: A Literature Survey

Due to the increasing growth of processing cores in complex computational systems, all the connection converted bottleneck for all systems. With the protection of progressing and constructing complex photonic connection on chip, optical data transmission is the best choice for replacing with electrical interconnection for the reason of gathering connection with a high bandwidth and insertion lo...

متن کامل

Biosensing microsystem platform based on the integration of Si Mach-Zehnder interferometer, microfluidics and grating couplers

We have achieved the design, fabrication and packaging of microfluidic networks with photonic sensors for novel labon-chip platforms which incorporate the on-chip biosensing detection. As sensors, we used an integrated Mach-Zehnder interferometer (MZI) based on TIR waveguides (Si/SiO2/Si3N4) of micro/nanodimensions for evanescent field detection of biomolecular interactions onto the sensing are...

متن کامل

Slow light Mach-Zehnder interferometer as label-free biosensor with scalable sensitivity.

The design, fabrication, and characterization of a label-free Mach-Zehnder interferometer (MZI) optical biosensor that incorporates a highly dispersive one-dimensional (1D) photonic crystal in one arm are presented. The sensitivity of this slow light MZI-based sensor scales with the length of the slow light photonic crystal region. The numerically simulated sensitivity of a MZI sensor with a 16...

متن کامل

Novelty low-cost integrated photonic biosensor using broadband source and on-chip spectral filter

Integrated label-free photonic biosensors provide an excellent limit of detection in combination with a low-cost disposable. Their application has thus far been limited by the necessity of an expensive tunable laser. In this article, we present a novel sensor, eliminating the tunable laser by combining a sensitive Mach-Zehnder interferometer with a broadband light source and an on-chip spectral...

متن کامل

-

In this paper a method for digitally recording four quarter-reference-wave-holograms (by CCD) in a Mach-Zehnder interferometer setup, and reconstructing the object wave-front by numerical method is presented. The terms of direct transmission, auto-correlation and conjugate wave in the four wave reconstruction are cancelled out and only one original object wave is left after overlapping. Reconst...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 6  شماره 

صفحات  -

تاریخ انتشار 2016