Off-Pump Coronary Artery Bypass Surgery Is Associated With Worse Arterial and Saphenous Vein Graft Patency and Less Effective Revascularization

نویسندگان

  • Laurie Shroyer
  • Scott J. Haugen
  • Janet H. Baltz
چکیده

Background—The Department of Veterans Affairs Randomized On/Off Bypass (ROOBY) trial compared clinical and angiographic outcomes in off-pump versus on-pump coronary artery bypass graft (CABG) surgery to ascertain the relative efficacy of the 2 techniques. Methods and Results—From February 2002 to May 2007, the ROOBY trial randomized 2203 patients to off-pump versus on-pump CABG. Follow-up angiography was obtained in 685 off-pump (62%) and 685 on-pump (62%) patients. Angiograms were analyzed (blinded to treatment) for FitzGibbon classification (A widely patent, B flow limited, O occluded) and effective revascularization. Effective revascularization was defined as follows: All 3 major coronary territories with significant disease were revascularized by a FitzGibbon A-quality graft to the major diseased artery, and there were no new postanastomotic lesions. Off-pump CABG resulted in lower FitzGibbon A patency rates than on-pump CABG for arterial conduits (85.8% versus 91.4%; P 0.003) and saphenous vein grafts (72.7% versus 80.4%; P 0.001). Fewer off-pump patients were effectively revascularized (50.1% versus 63.9% on-pump; P 0.001). Within each major coronary territory, effective revascularization was worse off pump than on pump (all P 0.001). The 1-year adverse cardiac event rate was 16.4% in patients with ineffective revascularization versus 5.9% in patients with effective revascularization (P 0.001). Conclusions—Off-pump CABG resulted in significantly lower FitzGibbon A patency for arterial and saphenous vein graft conduits and less effective revascularization than on-pump CABG. At 1 year, patients with less effective revascularization had higher adverse event rates. Clinical Trial Registration—URL: http://www.clinicaltrials.gov. Unique identifier: NCT00032630. (Circulation. 2012;125:2827-2835.)

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cardiovascular Surgery Off-Pump Coronary Artery Bypass Surgery Is Associated With Worse Arterial and Saphenous Vein Graft Patency and Less Effective Revascularization

Background—The Department of Veterans Affairs Randomized On/Off Bypass (ROOBY) trial compared clinical and angiographic outcomes in off-pump versus on-pump coronary artery bypass graft (CABG) surgery to ascertain the relative efficacy of the 2 techniques. Methods and Results—From February 2002 to May 2007, the ROOBY trial randomized 2203 patients to off-pump versus on-pump CABG. Follow-up angio...

متن کامل

Off-Pump coronary artery bypass surgery is associated with worse arterial and saphenous vein graft patency and less effective revascularization: Results from the Veterans Affairs Randomized On/Off Bypass (ROOBY) trial.

BACKGROUND The Department of Veterans Affairs Randomized On/Off Bypass (ROOBY) trial compared clinical and angiographic outcomes in off-pump versus on-pump coronary artery bypass graft (CABG) surgery to ascertain the relative efficacy of the 2 techniques. METHODS AND RESULTS From February 2002 to May 2007, the ROOBY trial randomized 2203 patients to off-pump versus on-pump CABG. Follow-up ang...

متن کامل

Major Leg Wound Complications After Saphenous Vein Harvest for Coronary Revascularization

Background: Major leg wound complications after coronary artery bypass graft procedures are infrequent and few are reported in the litrature.We present our experience in treating 30 patients with major leg wound complications after coronary revascularization procedures. Materials and Methods: A retrospective review of 2100 bypass procedures with saphenous veingraft performed over a 5-years p...

متن کامل

Routine intraoperative angiography improves the early patency of coronary grafts performed on the beating heart.

OBJECTIVES The techniques of performing coronary revascularization without cardiopulmonary bypass are rapidly evolving. However, concern remains regarding the accuracy of coronary artery anastomoses performed on the beating heart. This report reviews the use of intraoperative angiography in the critical appraisal of "off-pump" coronary artery bypass graft (CABG) surgery. PATIENTS Intraoperati...

متن کامل

Side-to-side Anastomosis Technique using Four Interrupted Sutures for Sequential Grafting with an Arterial Graft

Multivessel coronary artery bypass grafting (CABG) for complex or damaged small coronary lesions has been increasingly performed because of recent advances in percutaneous coronary intervention . Although sequential bypass using arterial grafts is essential for achieving complete revascularization and long-term patency with complex multivessel diseases, technical difficulty exists for patients ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012