Evanescent field absorption in a passive optical fiber resonator using continuous-wave cavity ring-down spectroscopy

نویسندگان

  • Peter B. Tarsa
  • Paul Rabinowitz
  • Kevin K. Lehmann
چکیده

We combine the sensitivity advantages of cavity ring-down spectroscopy (CRDS) with the versatility of optical fiber sensing technology in a spatially extended passive fiber ring resonator constructed of common telecommunications components. The resonator is characterized with both pulsed and continuous-wave diode laser excitation, and it is shown to be a practical device for direct measurement of loss in a fiber-optic system as well for CRDS sensing in liquids. We demonstrate a minimum detectable loss of 0.017% per p Hz and show near-infrared absorption of 1-octyne with a minimum detectable concentration of 0.049% per p Hz in non-interacting solvent at 1532.5 nm. 2003 Elsevier B.V. All rights reserved.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cavity Ring-down Biosensing

Cavity ring-down spectroscopy (CRDS) is an established technique for gases sensing that is newly emerging in the field of optical biosensing. This approach measures changes in the rate of decay of light injected into an optical resonator and relates them to optical loss along its length. This principle has recently been adapted for use in liquids, providing a highly sensitive method for quantit...

متن کامل

Single-cell detection by cavity ring-down spectroscopy

The implementation of cavity ring-down spectroscopy in an optical fiber resonator extends the viability of this highly sensitive technique for label-free detection of biological species. By chemically treating the surface of discrete tapered sensing regions along the length of a physically extended optical fiber resonator, we show single-cell sensitivity arising from optical scattering of the e...

متن کامل

Evanescent Wave Cavity Ring-down Spectroscopy: a Future Technology for Process Sensing

Evanescent wave cavity ring-down spectroscopy (EW-CRDS) is described. The total internal reflection (TIR)-ring and monolithic folded cavity designs are briefly discussed. The performance of EW-CRDS for trace water vapor detection is evaluated by accounting for surface chemical and physical properties as well as intrinsic resonator properties. INTRODUCTION Cavity ring-down spectroscopy (CRDS) us...

متن کامل

Cavity-enhanced spectroscopy in optical fibers.

Cavity-enhanced methods have been extended to fiber optics by use of fiber Bragg gratings (FBGs) as reflectors. High-finesse fiber cavities were fabricated from FBGs made in both germanium/boron-co-doped photosensitive fiber and hydrogen-loaded Corning SMF-28 fiber. Optical losses in these cavities were determined from the measured Fabry-Perot transmission spectra and cavity ring-down spectrosc...

متن کامل

Mid-infrared continuous wave cavity ring down spectroscopy of molecular ions using an optical parametric oscillator

A sensitive infrared detection scheme is presented in which continuous wave cavity ring down spectroscopy is used to record rovibrational spectra of molecular ions in direct absorption through supersonically expanding planar plasma. A cw optical parametric oscillator is used as a light source and combines a broad spectral coverage (2100–3600 cm ) and narrow bandwidth (7 kHz) with a high output ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2003