Evaluation of suspected interferents for TNT detection by ion mobility spectrometry.
نویسندگان
چکیده
The use of ion mobility spectrometry systems to detect explosives in high security situations creates a need to determine compounds that interfere and may compromise accurate detection. This is the first study to identify possible interfering air contaminants common in airport settings by IMS. Seventeen suspected contaminants from four major sources were investigated. Due to the ionization selectivity gained by employing chloride reactant ion chemistry, only 7 of the 17 compounds showed an IMS response. Of those seven compounds, only 4,6-dinitro-o-cresol (4,6DNOC) was found to have a similar mobility to 2,4,6-trinitrotoluene (TNT) with K(o) values of 1.55 and 1.50 cm(2) V(-1) s(-1), respectively. Although baseline resolution between TNT and 4,6DNOC was not achieved, the drift time for TNT was still easily identified. Alkyl-nitrated phenols, due to acidic fog, responded the strongest in the IMS. The effect of contamination on TNT sensitivity was investigated. Charge competition between TNT and 2,4-dinitrophenol (2,4DNP) was found to occur and to effect TNT sensitivity.
منابع مشابه
DETECTION AND MEASUREMENT OF ACETONE IN THE BREATH OF DIABETICS BY ION MOBILITY SPECTROMETRY METHOD
Background: The ion mobility spectrometry (IMS) is an analytical technique that is widely used due to its high sensitivity and speed for the detection of ionized molecules in gas phase and under atmospheric pressure. Breath analysis is a new method for obtaining information about person's clinical conditions that is considered by researchers. Human exhaled air contains a variety of components s...
متن کاملApplication of Ion Mobility Spectrometry for Determination of Morphine in Human Urine
In this study, a rapid, simple and sensitive ion mobility spectrometry (IMS) method with corona discharge as ionization source was described for the morphine determination in human urine. Morphine was extracted and purified from urine samples using solid phase extraction procedure with C18 column. It can offer the clean extracts which no extra peaks were observed in IMS. Under operating experim...
متن کاملAnalysis of explosives using electrospray ionization/ion mobility spectrometry (ESI/IMS).
The analysis of explosives with ion mobility spectrometry (IMS) directly from aqueous solutions was shown for the first time using an electrospray ionization technique. The IMS was operated in the negative mode at 250 degrees C and coupled with a quadrupole mass spectrometer to identify the observed IMS peaks. The IMS response characteristics of trinitrotoluene (TNT), 2,4-dinitrotoluene (2,4-DN...
متن کاملConstruction and characterization of a high-flow, high-resolution ion mobility spectrometer for detection of explosives after personnel portal sampling.
A novel analysis of explosives via the coupling of an airline passenger personnel portal with a high-flow (HF), high-resolution (HR) ion mobility spectrometry (IMS) was shown for the first time. The HF-HR-IMS utilized a novel ion aperture grid design with a (63)Ni ionization source while operating at ambient pressure in the positive ion mode at 200 degrees C. The HF-HR-IMS response characterist...
متن کاملA fluorescence turn-on mechanism to detect high explosives RDX and PETN.
Detecting hidden explosive devices in war zones and transportation hubs is a pressing concern. Current efforts have focused on sensing three commonly used powerful explosives: 2,4,6-trinitrotoluene (TNT), 1,3,5-trinitro-1,3,5-triazinane (RDX) and pentaerythritol tetranitrate (PETN) (Chart 1). The need for ultratrace detection of these low-volatility compounds has resulted in an intense interest...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Talanta
دوره 54 1 شماره
صفحات -
تاریخ انتشار 2001