Accelerated partial breast irradiation dosimetric criteria for the strut-adjusted volume implant.
نویسندگان
چکیده
PURPOSE Current guidelines for high-dose-rate accelerated partial breast irradiation using single-entry implants are based on the National Surgical Adjuvant Breast and Bowel Project B-39/Radiation Therapy Oncology Group 0413 protocol, which assumed a balloon implant geometry. We have developed robust plan evaluation criteria specifically for the strut-adjusted volume implant (SAVI). METHODS AND MATERIALS Plan evaluation criteria were established using a "training data set" of 62 SAVI treatment plans and included the percentage volume of target receiving 90%, 95%, and 100% of the prescription dose (V90, V95, and V100), the absolute volume of target receiving 150% and 200% of prescription (V150 and V200), and the maximum doses to skin (Dskin max) and ribs (Drib max). "Ideal" and "expected" (routinely achievable) thresholds were determined for each criterion and compared to B-39 guidelines. A "test data set" collected from the next 25 patients was analyzed using the developed plan evaluation criteria. RESULTS Ideal (expected) dosimetric thresholds established from the training data set were V90 ≥ 98% (95%), V95 ≥ 95% (92%), V100 ≥ 91% (88%), Dskin max < 90% (100%), and Drib max < 100%. Thresholds for V150 and V200 were stratified by SAVI size: V150 ≤ 30 cc (50 cc) and V200 ≤ 15 cc (20 cc) for 6-1 and Mini; V150 ≤ 50 cc (50 cc) and V200 ≤ 20 cc (20 cc) for 8-1 and 10-1. There was no significant difference between the training and test data sets in the fractions of patients meeting the criteria. Overall, 58% and 95% of 87 plans met all ideal and all expected criteria, respectively. CONCLUSIONS The plan evaluation criteria developed specifically for the SAVI device are robust, providing increased target coverage and increased skin sparing compared to B-39 guidelines.
منابع مشابه
Dosimetrical Evaluation and Clinical Implementation of a Strut-adjusted-volume-implant Savi Device Used for Accelerated Partial Breast Irradiation
The SAVI (the Strut Adjusted Volume Implant) device is one of the most novel devices used in Accelerated Partial Breast Irradiation (APBI). Various dosimetric parameters, as well as doses to adjacent critical structures, have been evaluated in 121 patients in this single institution 5-year retrospective study, using dose volume histogram (DVHs): Coverage Index (CI), cavity and planning target v...
متن کاملDosimetric performance of Strut-Adjusted Volume Implant: a new single-entry multicatheter breast brachytherapy applicator.
PURPOSE To evaluate the dosimetric performance and clinical utility of the Strut-Adjusted Volume Implant (SAVI) (Cianna Medical, Aliso Viejo, CA) applicator when used as the sole method of radiation therapy for patients with early breast carcinoma. METHODS AND MATERIALS The dosimetric performance of a Phase II clinical trial has been reported using the SAVI applicator for patients with early ...
متن کاملA study on dosimetry accuracy of Strut-Adjust Volume Implant (SAVI) brachytherapy
Introduction: Accelerated Partial Breast Irradiation (APBI) is an effective treatment for breast carcinomas because of its limited number of fractions. Strut-adjusted volume implant (SAVI) is a HDR brachytherapy applicator to deliver the prescription dose with good PTV coverage and acceptable dose to skin, chest wall and organ at risks. Acceptable clinical outcomes depend on a...
متن کاملComparison of planning techniques when air/fluid is present using the strut‐adjusted volume implant (SAVI) for HDR‐based accelerated partial breast irradiation
The presence of air/fluid surrounding implantable devices used for partial breast irradiation may significantly impact dose coverage to at-risk tissue. Of the 67 total patients retrospectively evaluated for this study, 32 (48%) had greater than 1 cc volume of air/fluid extending outside of the strut-adjusted volume implant (SAVI) device surface and were selected for comparison of planning appro...
متن کاملClinical implementation of a new HDR brachytherapy device for partial breast irradiation.
PURPOSE To present the clinical implementation of a new HDR device for partial breast irradiation, the Strut-Adjusted Volume Implant (SAVI), at the University of California, San Diego. METHODS AND MATERIALS The SAVI device has multiple peripheral struts that can be differentially loaded with the HDR source. Planning criteria used for evaluation of the treatment plans included the following do...