Endovenous laser ablation of great saphenous veins using a 1470 nm diode laser and the radial fibre--follow-up after six months.

نویسندگان

  • F Pannier
  • E Rabe
  • J Rits
  • A Kadiss
  • U Maurins
چکیده

BACKGROUND Endovenous laser ablation (EVLA) is an efficient method to treat insufficient great saphenous veins (GSV) with high occlusion rates. Most studies used 810, 940 or 980 nm diode lasers and a bare fibre. Moderate postoperative pain and bruising are frequent findings. Laser systems with higher wavelengths like 1470 nm with a higher absorption in water show less pain and bruising after the procedure. A newly-developed fibre (radial fibre, Biolitec) emits the laser energy radially around the tip directly into the venous wall contrary to the bare fibre.(9) The aim of this study was to demonstrate the outcome and side-effects after EVLA of GSV with a 1470 nm diode laser (Ceralas E, Biolitec) by using the radial fibre. METHODS Non-randomized, prospective study including 50 unselected limbs of 50 patients with a duplex sonographically verified incompetent GSV. EVLA was performed with a 1470 nm diode laser (Ceralas E, Biolitec) and a radial fibre. In the same session all insufficient tributaries were treated by phlebectomy. Tumescent local anaesthesia with 0.05% lidocaine was applied perivenously. Laser treatment was carried out in a continuous mode with a power of 15 W. Compression stockings (30 mmHg) were applied for one month. Postinterventional checkups took place one, 10, 30 days and six months after the procedure. RESULTS Three patients were lost to follow-up. The average linear endovenous energy density (LEED) was 90.8 J/cm vein (SD 35.3). At the six month follow-up all treated veins remained occluded and no new reflux in the treated segments occurred. No recurrent varicose veins had occurred so far. No severe complications such as deep venous thrombosis could be detected. In four patients at 30 days and three patients at six months local paresthesia occurred in the region of EVLA. Forty-four percent of patients did not have any pain after the treatment and 50% did not take any analgesic tablets at any time after the procedure. Postoperative ecchymoses in the track of the treated GSV was rare. In 80% of the limbs, no ecchymoses was observed after the treatment. CONCLUSION EVLA of GSV with a radially emitting laser fibre by using a 1470 nm diode laser is a safe and efficient treatment option.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Endovenous laser ablation of varicose perforating veins with the 1470-nm diode laser using the radial fibre slim.

BACKGROUND Endovenous Laser Ablation (EVLA) is one of the most accepted treatment options for varicose veins. The aim of this study was to investigate the efficacy and safety of the new radial fiber slim (ELVeS-radial-slim kit™) for the 1470 nm diode laser in perforator veins with a 1 month follow-up. METHODS Our prospective observational cohort study comprised 69 perforating veins in 55 pati...

متن کامل

Endovenous laser ablation of varicose veins with the 1470 nm diode laser using a radial fiber - 1-year follow-up.

BACKGROUND Endovenous laser ablation is one of the most accepted treatment options for insufficient great and small saphenous veins. The aim of this study was to investigate the long-term efficacy and safety of the radial fiber (ELVeS-radial kit™) for the 1470 nm diode laser in a 1-year follow-up. METHODS A total of 308 lower limbs with primary insufficiency of great and small saphenous veins...

متن کامل

Endovenous laser ablation of great and small saphenous vein incompetence with a 1470-nm laser and radial fiber.

OBJECTIVE Endovenous laser ablation (EVLA) of great (GSV) and small saphenous vein (SSV) chronic insufficiency with 1470-nm diode laser and radial fiber yields good short-term results. The aim of this study was to assess its efficacy after at least 12 months of follow-up. METHODS We performed a prospective interventional cohort study in an ambulatory care/day surgery setting. Consecutive pati...

متن کامل

Endovenous 1470 nm laser treatment of the saphenous vein: early report of pain assessment.

AIM The aim of the paper was to evaluate the rate of postoperative pain by using endovenous laser ablation with wave-length of 1470 nm for incompetent saphenous veins in our single center experience. METHODS A non-randomized prospective trial was performed. Patients with symptomatic varicose small saphenous vein and great saphenous vein were considered suitable for endovenous laser ablation. ...

متن کامل

Persistent below-knee great saphenous vein reflux after above-knee endovenous laser ablation with 1470-nm laser: a prospective study

Background: In endovenous laser ablation (EVLA), the great saphenous vein (GSV) is usually ablated from the knee to the groin, with no treatment of the below-knee segment regardless of its reflux status. However, persistent below-knee GSV reflux appears to be responsible for residual varicosities and symptoms of venous disease. Objectives: To evaluate clinical and duplex ultrasound (DUS) outcom...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Phlebology

دوره 26 1  شماره 

صفحات  -

تاریخ انتشار 2011