EM Advances Familiarity with radiation exposure dose from diagnostic imaging for acute pulmonary embolism and current patterns of practice

نویسندگان

  • Justin S. Ahn
  • Marcia L. Edmonds
  • Shelley L. McLeod
  • Jonathan F. Dreyer
چکیده

Objective: To assess the current level of knowledge and practice patterns of emergency physicians regarding radiation exposure from diagnostic imaging modalities for investigating acute pulmonary embolism (PE). Methods: An online survey was sent to adult emergency physicians working at two academic tertiary care adult emergency departments (EDs) to determine imaging choices for investigating PE in various patient populations and to assess their current knowledge of radiation doses and risks. A retrospective chart review was performed for all adult patients who underwent computed tomographic pulmonary angiography (CTPA) and/or ventilation-perfusion (V/Q) scanning in the same EDs. Results: The survey response rate was 72.1% (31 of 43 physicians). For patients , 30 years old, 83.9% of physicians chose V/Q scanning as their test of choice, regardless of gender. Although only a third of respondents knew the estimated radiation dose of a V/Q scan (37.5%) and a CTPA (32%), the majority were aware that V/Q scans involved less ionizing radiation than CTPAs. In the retrospective review, 663 charts were reviewed, including 201 CTPAs and 462 V/Q scans. V/Q scanning was the preferred modality in female patients (75.9% v. CTPA 24.1% [OR 2.1; 95% CI 1.5–2.9]) and in patients , 30 years old (87.9% v. CTPA 12.1% [OR 4.8; 95% CI 2.4–9.4]). Conclusions: Although surveyed physicians possessed limited knowledge of radiation doses of CTPA and V/Q scans, they preferentially used the lower radiation V/Q scans in younger patients, particularly females, in both the survey vignettes and in clinical practice. This may reflect efforts to reduce radiation exposures at our institution.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Familiarity with radiation exposure dose from diagnostic imaging for acute pulmonary embolism and current patterns of practice.

OBJECTIVE To assess the current level of knowledge and practice patterns of emergency physicians regarding radiation exposure from diagnostic imaging modalities for investigating acute pulmonary embolism (PE). METHODS An online survey was sent to adult emergency physicians working at two academic tertiary care adult emergency departments (EDs) to determine imaging choices for investigating PE...

متن کامل

Cumulative radiation exposure dose of diagnostic imaging studies in breast cancer patients

Background: Breast cancer is a common disease in radiation oncology. We evaluated the radiation dose received by breast cancer patients, an often-neglected concern. Materials and Methods: The total effective radiation dose in 101 breast cancer patients was calculated by summing the effective doses of individual diagnostic imaging tests from the first hospital visit to the initiation of radiothe...

متن کامل

Evaluation of the confounding factors disturbing the quality of CT images of pulmonary angiography

    Background: Since pulmonary angiography is the only non-invasive method for diagnosing pulmonary embolism, the use of radiation reduction methods without affecting the quality of images seems necessary. One of the simplest reasons for unnecessarily increasing of patient exposure is repetitive imaging due to poor image quality. Therefore, it is necessary to identify and ...

متن کامل

Clinical Review of Mustard Lung

More than 45,000 of 100,000 exposed patients are suffering from late effects of sulfur mustard (SM) after almost 20 years post-exposure. Respiratory complications of SM exacerbate over time and are the greatest cause of long-term disability in exposed patients. A triad of cough, expectoration and dyspnea has been found to be the main symptoms among patients. Even those who had not developed acu...

متن کامل

Four-Year Cumulative Radiation Exposure in Patients Undergoing Computed Tomography Angiography for Suspected Pulmonary Embolism

Purpose. The objective of this study was to determine the estimated effective radiation dose of pulmonary CT angiography (CTA) for suspected pulmonary embolism (PE) contributing to total medical radiation exposure over a 4-year period. Materials and Methods. This investigation retrospectively reviewed 300 patients who presented to the emergency department and received a pulmonary CTA scan for s...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014