Near infra-red interactance for nutritional assessment of dialysis patients.
نویسندگان
چکیده
BACKGROUND Malnutrition is a common problem in dialysis patients and may affect up to one-third of patients. Near-infrared interactance (NIR) is a novel approach to estimate body composition and per cent total body fat. METHODS We used near-infrared interactance (Futrex 5000) to estimate the body composition including body fat percentage, as well as subjective global assessment (SGA), anthropometric measurements including mid-arm circumference (MAC), triceps and biceps skinfold thickness, calculated mid-arm muscle circumference (MAMC), body mass index (BMI), and laboratory values. NIR score, SGA assessment and anthropometric parameters were measured shortly after the end of a dialysis session. NIR measurement was made by placing a Futrex sensor on the nonaccess upper arm for several seconds. Serum albumin, transferrin (reflected by total iron binding capacity), and total cholesterol concentrations were performed as well. RESULTS Thirty-four patients (20 men and 14 women) were selected from a pool of 120 haemodialysis patients. Their ages ranged from 26 to 86 years (58+/-14 years). Time on dialysis ranged from 8 months to 19 years (4.5+/-4.6 years). NIR scores were significantly different in three SGA groups: (A) well-nourished, 32.5+/-6.9%; (B) mildly to moderately malnourished, 29.2+/-5.3%; and (C) severely malnourished, 23.2+/-10.2% (P<0.001). Pearson correlation coefficients (r) between the NIR score and nutritionally relevant parameters were significant (P<0.001) for body mass index (r=+0.81), mid-arm circumference (r=+0.74), triceps skin fold (r=+0.54), biceps skin fold (r=+0.55), and mid-arm muscle circumference (r=+0.54). An inverse correlation was also found between NIR and years dialysed (r=-0.49, P=0.004), denoting a lesser body fat percentage according to NIR for patients dialysed longer. NIR was correlated with serum transferrin (r=+0.41, P=0.016) and cholesterol (r=+0.39, P=0.022) and marginally with serum albumin (r=+0.29, P=0.097). CONCLUSIONS We conclude that NIR, which can be performed within seconds, may serve as an objective indicator of nutritional status in haemodialysis patients. More comparative and longitudinal studies are needed to confirm the validity of NIR measurements in nutritional evaluation of dialysis patients.
منابع مشابه
Novel equations to estimate lean body mass in maintenance hemodialysis patients.
BACKGROUND Lean body mass (LBM) is an important nutritional measure representing muscle mass and somatic protein in hemodialysis patients, for whom we developed and tested equations to estimate LBM. STUDY DESIGN A study of diagnostic test accuracy. SETTING & PARTICIPANTS The development cohort included 118 hemodialysis patients with LBM measured using dual-energy x-ray absorptiometry (DEXA)...
متن کاملNovel Application of Near-infrared Spectroscopy and Chemometrics Approach for Detection of Lime Juice Adulteration
The aim of this study is to investigate the novel application of a handheld near infra-red spectrophotometer coupled with classification methodologies as a screening approach in detection of adulterated lime juices. For this purpose, a miniaturized near infra-red spectrophotometer (Tellspec®) in the spectral range of 900–1700 nm was used. Three diffuse reflectance spectra of 31 pure...
متن کاملValidation of Mini Nutritional Assessment Scale in peritoneal dialysis patients
INTRODUCTION Malnutrition is a negative predictive factor for survival in end stage renal disease (ESRD) patients. Coincidence of malnutrition, inflammation and atherosclerosis (MIA syndrome) in the dialysis population is an exceptionally poor outcome event. Due to flexibility, ease of performance and reproducibility, clinical scales are of particular value in assessment of nutritional status i...
متن کاملNovel Application of Near-infrared Spectroscopy and Chemometrics Approach for Detection of Lime Juice Adulteration
The aim of this study is to investigate the novel application of a handheld near infra-red spectrophotometer coupled with classification methodologies as a screening approach in detection of adulterated lime juices. For this purpose, a miniaturized near infra-red spectrophotometer (Tellspec®) in the spectral range of 900–1700 nm was used. Three diffuse reflectance spectra of 31 pure...
متن کاملA new approach for the estimation of body composition: infrared interactance.
A new method for the estimation of body composition in humans, called infrared interactance, is discussed. Infrared interactance is based on the principles of light absorption, reflection, and near-infrared spectroscopy. Body composition (percentage fat) was estimated in 53 adults (23 to 65 yr of age) by infrared interactance and compared to results from deuterium oxide dilution (r = 0.94), ski...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association
دوره 14 1 شماره
صفحات -
تاریخ انتشار 1999