Exothermic or heated processes create potentially unsafe work environments for an estimated 5-10 million American workers each year. Excessive heat and process contaminants have the potential to cause adverse health effects in exposed workers. Owing to the potential hazards, engineering controls are recommended for these processes. Our understanding of heat transfer and meteorological theories, and their applications for engineering controls have evolved since seminal work was published by Hemeon in 1955. These refined theories were reviewed and used to develop a proposed equation to estimate buoyant plume mean velocity. Mean velocity is a key parameter used to estimate the plume volumetric flow required for controlling effluents from exothermic processes. Subsequent to developing the proposed equation, plume velocity data were collected with a thermal anemometer for a model exothermic process in the laboratory, and an actual exothermic process in the field. Laboratory and field results were then compared to solutions provided by the proposed, American Conference of Governmental Industrial Hygienists (ACGIH), and Hemeon mean velocity equations. To determine which equation most closely matched the laboratory and field data, either t-tests or Wilcoxon Signed Rank tests were conducted (based on examination of data normality) to determine the difference between collected data and solutions from the proposed, ACGIH, and Hemeon equations. Median differences and P-values from Wilcoxon Signed Rank tests (nonparametric) indicate that the ACGIH mean velocity equation provides significantly different estimates from the laboratory and the field mean velocity data. However, the proposed and Hemeon equation provided solutions that were not significantly different from the collected data. These results were unexpected due to the similar developmental backgrounds between the ACGIH and Hemeon equations. Findings indicate that radiant heat flux is an important consideration when using horizontal plate heat transfer equations to estimate plume mean velocity over the range of parameters investigated. Results indicate that the mean velocity equation currently recommended by ACGIH is not as accurate as either the proposed or Hemeon equations over the range of parameters investigated.
منابع مشابه
Ventilation equations for improved exothermic process control.
Exothermic or heated processes create potentially unsafe work environments for an estimated 5-10 million American workers each year. Excessive heat and process contaminants have the potential to cause acute health effects such as heat stroke, and chronic effects such as manganism in welders. Although millions of workers are exposed to exothermic processes, insufficient attention has been given ...
متن کاملInvestigation on the Effect of Different Parameters in Wheeled Mobile Robot Error (TECHNICAL NOTE)
This article has focused on evaluation and identification of effective parameters in positioning performance with an odometry approach of an omni-directional mobile robot. Although there has been research in this field, but in this paper, a new approach has been proposed for mobile robot in positioning performance. With respect to experimental investigations of different parameters in omni-dire...
متن کاملIncremental Predictive Command of Velocity to Be Gained Guidance Method
In this paper, a new incremental predictive guidance method based on implicit form of velocity to be gained algorithm is proposed. In this approach, the generalized incremental predictive control (GIPC) approach is applied to the linearized model for compensating the guidance error. Instead of using the present state in popular model based predictive controller (MPC), in the new method both pre...
متن کاملAn Improved Control Approach for Dual Mechanical Coupled BLDC Motor With Nine-Switch Inverter
This paper presents the control approach for single inverter dual coupled brushless DC motors (DCBLDC) drive system. One of the basic requirements of such systems, is the power balance between two motors and on the other hand, minimizing mechanical fluctuations in order to avoid mechanical equipment damage especially in the state of mechanical resonance. This paper also presents an improved for...
متن کاملTheoretical and Experimental Investigation of the Key Components for a Rotary Desiccant Wheel
This paper describes the theoretical and experimental investigations of the key components and also the performance analysis of a rotary wheel for using as a solid desiccant dehumidifier and also indirect evaporator cooling system. Solid desiccants have long been used in dehumidification and cooling systems for energy efficiency or reduce electricity. Although many mathematical models on th...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Annals of occupational hygiene
دوره 51 4 شماره
صفحات -
تاریخ انتشار 2007