Accuracy of the freehand technique for 3 fixation methods in the C-2 vertebrae.
نویسندگان
چکیده
OBJECT Intraoperative imaging often does not provide adequate visualization to ensure safe placement of screws. Therefore, the authors investigated the accuracy of a freehand technique for placement of pars, pedicle, and intralaminar screws in C-2. METHODS Sixteen cadaveric specimens were instrumented freehand by 2 experienced cervical spine surgeons with either a pars or pedicle screw, and bilateral intralaminar screws. The technique was based on anatomical starting points and published screw trajectories. A pedicle finder was used to establish the trajectory, followed by tapping, palpation, and screw placement. After placement of all screws (16 pars screws, 16 pedicle screws, and 32 intralaminar screws), the C-2 segments were disarticulated, radiographed in anteroposterior, lateral, and axial planes, and meticulously inspected by another spine surgeon to determine the nature and presence of any defects. RESULTS A total of 64 screws were evaluated in this study. Pars screws exhibited 2 critical defects (1 in the foramen transversarium and 1 in the C2-3 facet) and an insignificant dorsal cortex breech, for an overall accuracy rate of 81.3%. Pedicle screws demonstrated only 1 insignificant violation (inferior facet/medial cortex intrusion of 1 mm) with an accuracy rate of 93.8%, and intralaminar screws demonstrated 3 insignificant violations (2 in the ventral canal, 1 in the caudad lamina breech) for an accuracy rate of 90.6%. Pars screws had significantly more critical violations than intralaminar screws (p = 0.041). CONCLUSIONS Instrumentation of the C-2 vertebrae using the freehand technique for insertion of pedicle and intralaminar screws showed a high success rate with no critical violations. Pars screw insertion was not as reliable, with 2 critical violations from a total of 16 placements. The freehand technique appears to be a safe and reliable method for insertion of C-2 pedicle and intralaminar screws.
منابع مشابه
Accuracy Assessment of Freehand Pedicular Screw Placement
Background: The purpose of this prospective study was to determine the accuracy of pedicular screw insertion withoutthe use of fluoroscopy.Methods: This study was conducted on patients with spinal diseases in need of pedicular screw fixation and fusion.The included patients suffered from such conditions as vertebral fracture, spinal stenosis, kyphosis, tumor, and pelvicf...
متن کاملInvestigation of Surgery Characteristics in Patients with Spondylolisthesis, Rasht, Iran from 2006 to 2011
Background & Aim: Spondylolisthesis is a visible deformity in lumbosacral region with vertebral slip and fracture or other deformities of pars interarticularis. This study aims at investigating the characteristics of spondylolisthesis surgery in operated patients. Methods & Materials/Patients: This is a retrospective study which included all the patients who had undergone spondylolisthesis ...
متن کاملBiomechanical Comparison Between Bashti Bone Plug Technique and Biodegradable Screw for Fixation of Grafts in Ligament surgery
Background: Ligament reconstruction is a common procedure in orthopedic surgery. Although several popular techniques are currently in use, new methods are proposed for secure fixation of the tendon graft into the bone tunnel. Purposes: We sought to introduce our new technique of Bashti bone plug for fixation of soft tissue graft in anterior cruciate ligament (ACL) reconstruction and to compar...
متن کاملClinical Results of Percutaneous Fixation of Pelvic and Acetabular Fractures: A Minimally Invasive Internal Fixation Technique
Background: The pelvic ring fractures (PRF) and acetabular fractures (AF) are among the major orthopedic injuriesassociated with high rates of morbidity and mortality. Open surgical stabilization is the standard treatment for themajority of these complications. Percutaneous minimally invasive surgical stabilization of the fractures has become anaccepted treatment method for th...
متن کاملبررسی میزان موفقیت در جاگذاری 180 پیچ پدیکولار بکاررفته در شکستگیهای ناپایدار ستون فقرات توراکولومبار با استفاده از رادیوگرافی ساده در حین عمل جراحی
Background & Aims: Thuracolumbar Unstable Fractures (T, L.U.F) are common after spine truma. Posterior pedicular fixation is a technique that is use for fixation of these fractures. This study evaluates the accuracy of pedicular screw placement in T, LUF with the assistance of plain radiography in operation rooms. Materials & Methods: This study is a case-control and analytical study. 35 pa...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Neurosurgical focus
دوره 31 4 شماره
صفحات -
تاریخ انتشار 2011