Clinical experience with a fourth-generation textured silicone gel breast implant: a review of 1012 Mentor MemoryGel breast implants.

نویسندگان

  • W Grant Stevens
  • Salvatore J Pacella
  • Andrew J L Gear
  • Mark E Freeman
  • Celeste McWhorter
  • Marissa J Tenenbaum
  • David A Stoker
چکیده

BACKGROUND Since the introduction of fourth- and fifth-generation silicone gel implants, manufacturers have conducted several prospective, multicenter trials to examine their safety and efficacy. However, these studies were not standardized with regard to surgeon skill, pocket placement, operative technique, adjunct therapies, or postoperative management. OBJECTIVE The purpose of this study was to examine the surgical outcomes of a single surgeon (WGS) in a consecutive series of breast augmentation cases using a fourth-generation cohesive silicone MemoryGel breast implant (Mentor, Santa Barbara, CA). METHODS A retrospective chart review was conducted to identify all patients who underwent silicone breast augmentation within the Mentor Adjunct Silicone MemoryGel breast implant by a single surgeon (WGS) within a single free-standing outpatient surgical center over a 13-year period (1992 to 2006). For each patient, demographic information, comorbidities, and surgical information (implant size and concomitant surgery) were recorded. In addition, outcomes were analyzed to identify complications and the need for surgical revision. RESULTS A total of 1012 fourth-generation, textured, cohesive silicone gel implants were placed in 511 patients during the 13-year study period. The overall complication rate per implant was 5.5% (n=56 implants in 43 patients). The most common complication was capsular contracture (n=26; 2.6 %) followed by abnormal scarring (n=11; 1.1%). The overall revision rates per patient and per implant were 8.0% (n = 41 patients) and 6.8% (n = 69 implants), respectively. The average time interval between initial implantation and revision was 18.5 months (range, 2 weeks to 26 months). The most common indication for surgical revision was patient desire for implant size change (n=15 patients) followed by Baker class III or IV capsular contracture (n=13 patients). The presence of previous surgery for capsular contracture was not statistically correlated to the need for revision (P= .326). Age (P= .568), previous history of breast surgery (P= .704), and history of smoking (P= .138) were also not statistically correlated to revision. Placement of the implant in the subglandular position (n=30 implants), however, was statistically correlated with need for revision (P< .01). CONCLUSIONS Mentor fourth-generation cohesive silicone gel implants possess a complication and revision profile that is superior to earlier-generation silicone gel implants. Implantation with MemoryGel implants, when standardized with regard to surgeon and operative technique, can have significantly reduced complication and revision rates compared to the Mentor Core Data.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Ten-year review of a prospective randomized controlled trial of textured versus smooth subglandular silicone gel breast implants.

Although textured silicone breast implants have been shown to reduce the incidence of capsular contracture, there is little evidence if this effect is maintained in the long term. It has been 10 years since the double-blind randomized trial in which 53 patients received either Mentor smooth (26) or textured silicone gel implants (27). Of the 14 patients who were not known to have developed a co...

متن کامل

Silicone Gel Breast Implants : Science and Testing COSMETIC

47S Before 1963, implants of any type were rarely used to augment the breast. Cronin and Gerow introduced a first-generation breast implant, and since these were brought to market, many iterations of the original product have been developed.1 From January 1992 to November 2006, the use of silicone implants was highly restricted and not available to first-time and nonreconstructive patients.2 Ma...

متن کامل

Silicone Gel Bleed on Breast Implants

Silicone is a polymer widely used for medical purposes, including breast implants. The aim of this work is to verify the occurrence of silicone gel diffusion through the lining membrane (bleed) of gel breast implants with smooth, textured, and polyurethane foam coated surfaces, sterilized by dry heat and ethylene oxide. The results enable us to conclude that there is significant difference for ...

متن کامل

A comparison of 500 prefilled textured saline breast implants versus 500 standard textured saline breast implants: is there a difference in deflation rates?

BACKGROUND This study provides the first large-volume (1000 implant) comparison of the deflation rates of Poly Implant Prosthesis prefilled textured saline breast implants versus a control group of Mentor Siltex textured saline implants. METHODS A consecutive series of 500 Poly Implant Prosthesis prefilled textured saline breast implants was compared with a consecutive series of 500 Mentor Si...

متن کامل

Early experience with an anatomical soft cohesive silicone gel prosthesis in cosmetic and reconstructive breast implant surgery.

Recently, an anatomic breast implant filled with soft cohesive silicone gel was introduced by Mentor Medical Systems onto the European market. This study reports the early experience of a single surgeon with this implant. All patients who received a Contour Profile Gel (CPG) implant from March 2001 to October 2002 were studied. Patient satisfaction with breast shape and consistency was assessed...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Aesthetic surgery journal

دوره 28 6  شماره 

صفحات  -

تاریخ انتشار 2008