Analyzing the Harmonic Distortion in a Distribution System Caused by the Non-Linear Residential Loads
نویسندگان
چکیده
Harmonic distortion has garnered a lot of interest in the recent past due to the high advent of the non-linear electronic loads. Moreover, newer technologies including distributed generation and electric vehicles are anticipated to be part of the distribution systems at a mass scale in the near future. This makes it of utmost importance to evaluate the existing power distribution systems and analyze the possible constraints. This research study makes an effort to evaluate the harmonic distortion in the distribution systems caused by the various non-linear residential loads. The experimentally developed harmonic spectrums, of several home appliances, are deployed for the simulation of a typical UK distribution system using Electrical Transient Analyzer Program (ETAP). The results show high level of harmonic distortion, at the Point of Common Coupling (PCC), in the distribution system which becomes even more aggravated when a higher loading level, of the distribution transformer, is considered.
منابع مشابه
An Intelligent Method Based on WNN for Estimating Voltage Harmonic Waveforms of Non-monitored Sensitive Loads in Distribution Network
An intelligent method based on wavelet neural network (WNN) is presented in this study to estimate voltage harmonic distortion waveforms at a non-monitored sensitive load. Voltage harmonics are considered as the main type of waveform distortion in the power quality approach. To detect and analyze voltage harmonics, it is not economical to install power quality monitors (PQMs) at all buses. The ...
متن کاملThe New Definitions for the Power Terms in Distorted and Unbalanced Conditions and Calculation of these Terms for an Electric Arc Furnace
The rapid increase of non-linear loads in the last three decades has caused electrical quantities such as voltages and currents in 3-phase distribution systems to become distorted waveforms. This paper reviews, explains and discusses some new concepts, definitions and new available theory in the unbalanced and distorted systems. The usefulness of the proposed practical definitions is investigat...
متن کاملThe New Definitions for the Power Terms in Distorted and Unbalanced Conditions and Calculation of these Terms for an Electric Arc Furnace
The rapid increase of non-linear loads in the last three decades has caused electrical quantities such as voltages and currents in 3-phase distribution systems to become distorted waveforms. This paper reviews, explains and discusses some new concepts, definitions and new available theory in the unbalanced and distorted systems. The usefulness of the proposed practical definitions is investigat...
متن کاملA new method based on fuzzy system and gravitational optimal detector for capacitor placement, considering nonlinear loads
This paper describes an advantageous method for using the capacitor banks in the distribution network, optimally. The aim is to determine the count, location and capacitor values in order to minimize the annual cost resulting from energy losses and capacitor bank’s installation cost. Besides, in the case of having nonlinear loads in the network, by installing capacitors in appropriate locations...
متن کاملReliability Assessment of Distribution Transformers Considering Load Harmonics
The progressive application of non-linear loads in distribution systems (DS) increases current harmonics flow in DS's apparatuses, especially distribution transformers (DTs). Since DTs' operating temperature rises due to the harmonics flow, their loading should be reduced such that the hot spot temperature (HST) is preserved under its permissible value. This means that DTs' available capacity i...
متن کامل