Atrial Fibrillation is Associated with Increased Pacemaker Implantation Rates in the Placement of AoRTic Transcatheter Valve (PARTNER) Trial.
نویسندگان
چکیده
Atrial fibrillation (AF) is associated with worse outcomes in many cardiovascular diseases. There are few data examining pacemaker implantation rates and indications in patients with AF who undergo transcatheter aortic valve replacement (TAVR). To examine the impact of AF on the incidence of and indications for pacemakers in patients undergoing TAVR, we evaluated data of 1723 patients without pre-existing pacemakers who underwent TAVR in the Placement of AoRTic TraNscathetER Valve (PARTNER) trial. Permanent pacemaker implantation rates and indications were compared in groups based on baseline and discharge heart rhythm: sinus rhythm (SR) vs. AF. 1211 patients manifested SR at baseline/SR at discharge (SR/SR), 105 SR baseline/AF discharge (SR/AF), and 407 AF baseline/AF discharge (AF/AF). Patients who developed and were discharged with AF (SR/AF) had the highest rates of pacemaker implantation at 30 days (13.7% SR/AF vs. 5.4% SR/SR, p=0.0008 and 5.9% AF/AF, p=0.008) and 1 year (17.7% SR/AF vs. 7.1% SR/SR, p=0.0002 and 8.1% AF/AF, p=0.0034). Conversion from SR to AF by discharge was an independent predictor of increased pacemaker implantation at 30 days (HR 2.19 vs. SR/SR, 95% CI 1.23-3.93, p=0.008) and 1 year (HR 1.91 vs. SR/SR, 95% CI 1.33-3.80). Pacemaker indications differed between groups, with relatively more implanted in the AF groups for sick sinus syndrome (SSS) versus AV block. In conclusion, conversion to AF is an independent predictor of permanent pacemaker implantation in TAVR patients. Indications differ depending on heart rhythm, with patients in AF manifesting clinically significant tachy-brady syndrome versus AV block.
منابع مشابه
Atrial Fibrillation Is Associated With Increased Mortality in Patients Undergoing Transcatheter Aortic Valve Replacement: Insights From the Placement of Aortic Transcatheter Valve (PARTNER) Trial.
BACKGROUND This study sought to evaluate the impact of atrial fibrillation (AF) on clinical outcomes in patients undergoing transcatheter aortic valve replacement. METHODS AND RESULTS Data were evaluated in 1879 patients with baseline and discharge ECGs who underwent transcatheter aortic valve replacement in the Placement of AoRTic TraNscathetER Valve (PARTNER) trial. A total of 1262 patients...
متن کاملLetter by Levy and Tribouilloy Regarding Article, "Atrial Fibrillation Is Associated With Increased Mortality in Patients Undergoing Transcatheter Aortic Valve Replacement: Insights From the Placement of Aortic Transcatheter Valve (PARTNER) Trial".
To the Editor: We read with great interest the article by Biviano et al, which addressed the impact of atrial fibrillation (AF) on clinical outcome in patients undergoing transcatheter aortic valve replacement. The authors brilliantly showed that for transcatheter aortic valve replacement patients, AF is associated with increased mortality at 30 days and 1 year, and repeat hospitalizations at 1...
متن کاملLetter by Amat-Santos et al Regarding Article, "Atrial Fibrillation Is Associated With Increased Mortality in Patients Undergoing Transcatheter Aortic Valve Replacemen: Insights From the Placement of Aortic Transcatheter Valve (PARTNER) Trial".
To the Editor: We read with great interest the article from Biviano et al. We think that their findings are of utmost importance for the prognostic assessment of patients following transcatheter aortic valve replacement. In this study, the rate of new-onset atrial fibrillation (AF) as reported in the ECG performed at discharge was 6%. This rate is low in comparison with previously reported rese...
متن کاملTiming, predictive factors, and prognostic value of cerebrovascular events in a large cohort of patients undergoing transcatheter aortic valve implantation.
BACKGROUND The objective of this study was to evaluate the timing, predictive factors, and prognostic value of cerebrovascular events (CVEs) after transcatheter aortic valve implantation. METHODS AND RESULTS The study included 1061 consecutive patients who underwent transcatheter aortic valve implantation with a balloon-expandable (64%) or self-expandable (36%) valve. CVEs were classified as ...
متن کاملIntrinsic Atrioventricular Node Conduction Recovery After Transcatheter Aortic Valve Implantation and the Permanent Pacemaker Implantation Enigma
The prevalence of degenerative valvular diseases such as aortic stenosis has continued to rise due to an increase in the aging population globally [1, 2]. Transcatheter aortic valve implantation (TAVI) has emerged to the forefront of severe aortic stenosis treatment, starting with high-risk surgical patients [1, 2]. The minimally invasive approach of TAVI, as established from the promising resu...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of atrial fibrillation
دوره 10 1 شماره
صفحات -
تاریخ انتشار 2017