Do Questions Reflecting Indoor Air Pollutant Exposure from a Questionnaire Predict Direct Measure of Exposure in Owner-Occupied Houses?

نویسندگان

  • C.K. Jennifer Loo
  • Richard G. Foty
  • Amanda J. Wheeler
  • J. David Miller
  • Greg Evans
  • David M. Stieb
  • Sharon D. Dell
چکیده

Home characteristic questions are used in epidemiological studies and clinical settings to assess potentially harmful exposures in the home. The objective of this study was to determine whether questionnaire-reported home characteristics can predict directly measured pollutants. Sixty home inspections were conducted on a subsample of the 2006 population-based Toronto Child Health Evaluation Questionnaire. Indoor/outdoor air and settled dust samples were analyzed. Mean Fel d 1 was higher (p < 0.0001) in homes with a cat (450.58 μg/g) versus without (22.28 μg/g). Mean indoor NO(2) was higher (p = 0.003) in homes with gas stoves (14.98 ppb) versus without (8.31 ppb). Self-reported musty odours predicted higher glucan levels (10554.37 μg/g versus 6308.58 μg/g, p = 0.0077). Der f 1 was predicted by the home's age, but not by reports of carpets, and was higher in homes with mean relative humidity > 50% (61.30 μg/g, versus 6.24 μg/g, p = 0.002). Self-reported presence of a cat, a gas stove, musty odours, mice, and the home's age and indoor relative humidity over 50% predicted measured indoor levels of cat allergens, NO(2), fungal glucan, mouse allergens and dust mite allergens, respectively. These results are helpful for understanding the significance of indoor exposures ascertained by self-reporting in large epidemiological studies and also in the clinical setting.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Investigation of indoor air pollution by chlorpyrifos: Determination of chlorpyrifos in indoor air and 3,5,6-trichloro-2-pyridinol in residents' urine as an exposure index.

OBJECTS We carried out an investigation to clarify the real state of indoor air pollution by chlorpyrifos (termiticide) and exposure to chlorpyrifos of residents by measuring its urinary metabolite 3,5,6-trichloro-2-pyridinol (TCP) as an exposure index, such as biological monitoring. METHODS The investigation was conducted in 43 individual houses with termiticide application (whether the term...

متن کامل

Indoor Radon Measurement in Dwellings of Khorramabad City, Iran

Introduction: Exposure to indoor radon increases the risk of lung cancer. This study examined the level of indoor radon in dwellings of Khorramabad city, by using passive alpha-track detector (CR-39) during winter of 2016. Materials and Methods: In the present study, we detected the concentration of indoor radon in 56 dwellings. A passive sampling instrument (alpha-track detector with CR-39 pol...

متن کامل

Occupational exposure to hazardous airborne pollutants: effects of air mixing and source location.

The presence of airborne pollutants in indoor environments has been associated with occupants' discomfort and/or adverse health effects. This study investigates occupational exposure in relation to indoor air mixing and source location relative to a human body. Experimental and computational methods were used to provide information about the pollutant distribution in the vicinity of the human b...

متن کامل

Indoor Smoke Exposure and Risk of Anthracosis

The association between indoor smoke exposure due to traditional baking (baking homemade bread) and anthracosis has rarely been investigated. The aim of the present study is to quantify such association among the Iranian population. A hospital based case-control study was carried out on 83 anthracotic cases and 155 controls (83 individuals with non-anthracotic pulmonary disorders from the pulmo...

متن کامل

دز دریافتی مردم رامسر در اثر مواجهه با پرتوهای گاما در داخل منازل

The coastal area of ​​Ramsar in northern of Iran located in the province of Mazandaran has been known as the highest levels of natural radiation background in the world. The background radiation is mainly due to the presence of radioactive isotopes of the radium element and its decay products, which is brought to the surface by hot springs. In this study, the indoor gamma dose rate in Ramsar wa...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 7  شماره 

صفحات  -

تاریخ انتشار 2010