Separate effects of the microkeratome incision and laser ablation on the eye's wave aberration.
نویسندگان
چکیده
PURPOSE To study the optical changes induced by the microkeratome cut, the subsequent laser ablation, and the biomechanical healing response of the cornea in normal laser in situ keratomileusis (LASIK) eyes. DESIGN Prospective randomized clinical trial. METHODS A Hansatome microkeratome was used to cut a corneal flap in one eye (study eye) of 17 normal myopic patients and a subsequent laser ablation was performed 2 months after this initial microkeratome incision. Control eyes received conventional LASIK treatments at the latter time point. The wave aberration of both the study and contralateral control eyes were measured over a 6-mm pupil with a Shack-Hartmann wavefront sensor for all preoperative, postflap cut, and postablation visits. RESULTS The eye's higher order aberrations had a small, but significant increase (P =.03) of approximately 30% 2 months after cutting a flap. No systematic changes were observed in nearly all Zernike coefficients from their preoperative levels at 2 months postflap cut. A significant difference between the study and control eyes was observed for one trefoil mode, Z(3)(3) (P =.04). CONCLUSIONS There was a wide variation in the response of individual Zernike modes across patients after cutting a flap. The majority of spherical aberration induced by the LASIK procedure seems to be due to the laser ablation and not the microkeratome cut. In addition, the total and higher order root mean square of wavefront errors were nearly identical for both the study and control eyes 3-months after the laser ablation, indicating that a procedure in which the incision and the ablation are separated in time to better control aberrations does not compromise the outcome of a conventional LASIK treatment.
منابع مشابه
Comparison of higher-order aberration induction between manual microkeratome and femtosecond laser flap creation.
PURPOSE To compare the mean change in aberrations produced by a mechanical microkeratome and femtosecond laser. METHODS This was a retrospective study of 62 consecutive near emmetropic eyes that underwent LASIK and satisfied the following criteria: negligible laser ablation (for spherical equivalent of 0.00 to +0.50 diopters and maximum meridian of +0.50 diopters), and preoperative and at lea...
متن کاملCT-guided laser probe for ablation of brain tumors
In this study, 22 patients (15-75 years old) were selected and transferred to CT scan for tumor ablation. For ablations, after prep and drep under the local anesthesia and mild sedation in proper position, small incision made and special needle inserted and guided by proper direction to the core of the tumor. Then, laser probe inserted through the needle and laser energy delivered. Although we ...
متن کاملImprovement in retinal image quality with dynamic correction of the eye's aberrations.
We measured the improvement in retinal image quality provided by correcting the temporal variation in the eye's wave aberration with a closed-loop adaptive optics system. This system samples the eye's wave aberration at rates up to 30 Hz. Correction of the eye's aberrations can be completed in 0.25-0.5 seconds, resulting in residual rms wave-front errors as low as 0.1 microns for 6.8 mm pupils....
متن کاملAcute toxicity of synthetic colloidal silver nanoparticles produced by laser ablation method to Eastern mosquitofish, Gambusia holbrooki
Considering the growing production, consumption of nanomaterials and their probable release into the aquatic ecosystems and study on the toxic effects of these materials are of critical importance to aquatic organisms. In this study, the acute toxicity of silver nanoparticles (AgNPs) produced by a physical method (laser ablation) was examined on Gambusia fish. Acute toxicity tests were planned ...
متن کاملEffect of the polarization on ocular wave aberration measurements.
Measurement of the eye's wave aberrations has become fairly standard in recent years. However, most studies have not taken into account the possible influence of the polarization state of light on the wave aberration measurements. The birefringence properties of the eye's optical components, in particular corneal birefringence, can be expected to have an effect on the wave aberration estimates ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- American journal of ophthalmology
دوره 136 2 شماره
صفحات -
تاریخ انتشار 2003