Combined long- and short-axis myocardial perfusion cardiovascular magnetic resonance.
نویسندگان
چکیده
PURPOSE To date, myocardial perfusion cardiovascular magnetic resonance (CMR) has been reported in single and multiple short-axis slices. Three short-axis planes can assess 16 segments of the standard 17-segment myocardial model, but this approach fails to assess the ventricular apex that requires at least one long-axis plane. We therefore evaluated the feasibility and benefit of combined long- and short-axis perfusion CMR to enable complete 17 segments coverage for comprehensive myocardial perfusion assessment. METHODS AND MATERIALS Using a hybrid echo planar imaging (EPI) sequence, we performed rest and adenosine stress first-pass perfusion CMR studies with 3 short-axis (basal, mid, apical) planes, and additional long-axis planes in the same cardiac cycle in a broad range of cardiology patients. RESULTS Perfusion CMR was performed in 53 consecutive patients using the combined short-long-axis imaging protocol. Twenty-nine of those studied had known or suspected coronary artery disease (CAD), 18 hypertrophic cardiomyopathy, and 6 suspected microvascular perfusion abnormalities. In 39 patients (70%), it was possible to acquire 5 slices at rest and stress including both the horizontal and vertical long axes. In 15 patients (27%), only one long-axis could be acquired, and in 2 patients (5%) only 3 slices (short axis) could be obtained. However, in none of the patients with known or suspected CAD was apical ischemia demonstrated by the long-axis views, despite apical ischemia having been demonstrated with recent SPECT studies in 8 of these patients. CONCLUSION Rest-stress myocardial perfusion CMR is able to achieve complete segmental coverage of the myocardium using the combined short-long axis approach using an EPI sequence in 97% of a long series of consecutive cardiology patients, while maintaining excellent spatial resolution. However, the long-axis views were not found to be able to demonstrate inducible perfusion defects in the apex.
منابع مشابه
A combined method for the determination of myocardial perfusion in experimental animals using microspheres and CMR.
A convenient method is introduced for myocardial perfusion research by combining multislice short-axis cine cardiovascular magnetic resonance (MSA-CMR) and colored microspheres (CM). In canine control-ischemia-reperfusion (n = 11), Cardiac output (CO) was measured using MSA-CMR (COMSA), Phase Contrast CMR (PC-CMR, COPC) and CM (from reference blood samples, COmicro) in 3 experimental periods pe...
متن کاملCardiovascular magnetic resonance assessment in previously repaired ALCAPA
Methods 6 patients with repaired ALCAPA (2 Tackeuchi, 4 direct re-implantation) underwent CMR to assess clinical suspicion of myocardial ischemia short axis and long axis cine images (assess ventricular function), late-gadolinium enhancement (detect myocardial fibrosis), adenosine stress perfusion scan (detection of reversible ischaemia) and 3D whole-heart imaging (visualization of proximal cor...
متن کاملInterstudy reproducibility of quantitative perfusion cardiovascular magnetic resonance.
PURPOSE To determine the interstudy reproducibility of quantitative first-pass perfusion cardiovascular magnetic resonance with comparison of 2 previously described analysis techniques. There is no published data on the interstudy reproducibility of perfusion cardiovascular magnetic resonance which can be used to determine the significance of longitudinal changes in myocardial perfusion after p...
متن کاملCombined myocardial stress perfusion imaging and myocardial stress tagging for detection of coronary artery disease at 3 Tesla
BACKGROUND Adenosine stress perfusion is very sensitive for detection of coronary artery disease (CAD), and yields good specificity. Standard adenosine cine imaging lacks high sensitivity, but is very specific. Myocardial tagging improves detection of wall motion abnormalities (WMAs). Perfusion and tagging cardiovascular magnetic resonance (CMR) both benefit from high field imaging (improved co...
متن کاملMyocardial perfusion reserve in cardiovascular magnetic resonance: Correlation to coronary microvascular dysfunction.
The present study examined the association of myocardial perfusion reserve index (MPRI) in cardiovascular magnetic resonance (CMR) with coronary microvascular dysfunction (CMD) and serum levels of markers of inflammation or endothelial activation. Twelve patients with typical angina pectoris without coronary artery disease were enrolled in this study, and CMR perfusion was analyzed using a stea...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance
دوره 6 4 شماره
صفحات -
تاریخ انتشار 2004