Comparability of Point-of-Care versus Central Laboratory Hemoglobin Determination in Emergency Patients at a Supra-Maximal Care Hospital

نویسندگان

  • Ramona C. Dolscheid-Pommerich
  • Sarah Dolscheid
  • Daniel Grigutsch
  • Birgit Stoffel-Wagner
  • Ingo Graeff
چکیده

Fulfilling the requirements of point-of-care testing (POCT) training regarding proper execution of measurements and compliance with internal and external quality control specifications is a great challenge. Our aim was to compare the values of the highly critical parameter hemoglobin (Hb) determined with POCT devices and central laboratory analyzer in the highly vulnerable setting of an emergency department in a supra maximal care hospital to assess the quality of POCT performance. In 2548 patients, Hb measurements using POCT devices (POCT-Hb) were compared with Hb measurements performed at the central laboratory (Hb-ZL). Additionally, sub collectives (WHO anemia classification, patients with Hb <8 g/dl and suprageriatric patients (age >85y.) were analyzed. Overall, the correlation between POCT-Hb and Hb-ZL was highly significant (r = 0.96, p<0.001). Mean difference was -0.44g/dl. POCT-Hb values tended to be higher than Hb-ZL values (t(2547) = 36.1, p<0.001). Standard deviation of the differences was 0.62 g/dl. Only in 26 patients (1%), absolute differences >2.5g/dl occurred. McNemar´s test revealed significant differences regarding anemia diagnosis according to WHO definition for male, female and total patients (♂ p<0.001; ♀ p<0.001, total p<0.001). Hb-ZL resulted significantly more often in anemia diagnosis. In samples with Hb<8g/dl, McNemar´s test yielded no significant difference (p = 0.169). In suprageriatric patients, McNemar´s test revealed significant differences regarding anemia diagnosis according to WHO definition in male, female and total patients (♂ p<0.01; ♀ p = 0.002, total p<0.001). The difference between Hb-ZL and POCT-Hb with Hb<8g/dl was not statistically significant (<8g/dl, p = 1.000). Overall, we found a highly significant correlation between the analyzed hemoglobin concentration measurement methods, i.e. POCT devices and at the central laboratory. The results confirm the successful implementation of the presented POCT concept. Nevertheless some limitations could be identified in anemic patients stressing the importance of carefully examining clinically implausible results.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Retrospective Evaluation of the Accuracy of Point of Care Versus Central Laboratory Sodium Measurements at a Supra Maximal Care Hospital

Citation: Dolscheid-Pommerich, R.C., et al. Retrospective Evaluation of the Accuracy of Point of Care Versus Central Laboratory Sodium Measurements at a Supra Maximal Care Hospital. (2018) J Anesth Surg 5(1): 22-26. Received date: January 31, 2018 Accepted date: February 16, 2018 Published date: February 22, 2018 Ramona C. Dolscheid-Pommerich1*, Sarah Dolscheid2, Lars Eichhorn3, Birgit Stoffel-...

متن کامل

Identifying high and low serum-ascites albumin gradient in ascitic fluid by the point of care dipstick test

Objective: To evaluate the capability of ascitic fluid dipstick results for pH, glucose, and protein in order to predict a low serum-ascites albumin gradient (SAAG) at the bedside of the patient in the emergency department (ED). Methods: This prospective cross-sectional study was conducted during one year in the ED of Afzalipour hospital in Kerman, Iran. ...

متن کامل

The Clinical Spectrum of Plumbism; an Experience from a Tertiary Care Hospital in Karachi, Pakistan

Background:Lead toxicity continues to remain a concerning health problem for developing nations like Pakistan. Due to the lack of studies, we aim to highlight the clinical spectrum of lead poisoning in patients presenting to an urban-based tertiary care hospital in Pakistan. Method:This is a retrospective review of patients admitted form January 2011 to December 2014 using a structured question...

متن کامل

Association of Acute Phase Reactants with COVID-19-related Severity and Mortality: A Study in a Tertiary Care Hospital in India

Background and Objectives: The outbreak of coronavirus disease 2019 (COVID-19) has become a public health emergency. This study aimed to investigate a possible correlation between COVID-19 severity and mortality and serum levels of ferritin and C-reactive protein (CRP). Methods: This retrospective descriptive study was conducted on 75 COVID-19 patients hospitalized in a tertiary care hospital ...

متن کامل

The Comparison of the Point-of-Care Serum Procalcitonin Assay Method with the BRAHMS Certified Method

Background and Aims: As a method for the diagnosis and management of sepsis, the serum procalcitonin assay is routinely used, especially in the emergency department (ED) and intensive care units (ICU). Procalcitonin has reasonable diagnostic accuracy for bacteremia in hospitalized patients of all age groups with suspected infection or sepsis. This study aimed to compare the Getein Biotech proca...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 11  شماره 

صفحات  -

تاریخ انتشار 2016