Calibration and validation of confocal spectral imaging systems.
نویسندگان
چکیده
BACKGROUND Confocal spectral imaging (CSI) microscopic systems currently on the market delineate multiple fluorescent proteins, labels, or dyes within biological specimens by performing spectral characterizations. However, some CSI systems have been found to present inconsistent spectral profiles of reference spectra within a particular system and between related and unrelated instruments. This variability confirms that there is a need for a standardized, objective calibration and validation protocol. METHODS Our protocol uses an inexpensive multi-ion discharge lamp (MIDL) that contains Hg(+), Ar(+), and inorganic fluorophores that emit distinct, stable, spectral features in place of a sample. We derived reference spectra from the MIDL data to accurately predict the spectral resolution, ratio of wavelength to wavelength, contrast, and aliasing parameters of any CSI system. We were also able to predict and confirm the influence of pinhole diameter on spectral profiles. RESULTS Using this simulation, we determined that there was good agreement between observed and theoretical expectations, thus enabling us to identify malfunctioning subsystems. We examined eight CSI systems and one nonconfocal spectral system, all of which displayed spectral inconsistencies. No instrument met its optimal performance expectations. In two systems, we established the need for factory realignment that had not been otherwise recognized. CONCLUSIONS We found that using a primary light source that emits an absolute standard "reference spectrum" enabled us to diagnose instrumental errors and measure accuracy and reproducibility under normalized conditions. With this information, a CSI operator can determine whether a CSI system is working optimally and make objective comparisons with the performance of other CSI systems. We determined that, if CSI systems were standardized to produce the same spectral profile of a MIDL lamp, researchers could be confident that the same experimental findings would be obtained on any CSI system.
منابع مشابه
Simple Tool for the Standardisation of Confocal Spectral Imaging Systems
Spectral fluorescence standards like dyes C-E with known corrected, i.e., instrument-independent broad and unstructured emission spectra (Ic(λem)) that present chemical equivalents of calibration lamps, are simple tools for the determination of the relative spectral responsivity or sensitivity (s(λem)) of the emission channel of fluorescence instruments under application-relevant conditions [2]...
متن کاملUV-Vis Spectrophotometry and Multivariate Calibration Method for Simultaneous Determination of Theophylline, Montelukast and Loratadine in Tablet Preparations and Spiked Human Plasma
Resolution of binary mixtures of theophylline (THEO), montelukast (MKST) and loratadine (LORA) with minimum sample pretreatment and without analyte separation has been successfully achieved by multivariate spectrophotometric calibration, together with partial least-squares (PLS-1), principal component regression (PCR) and hybrid linear analysis (HLA). Data of analysis were obtained from UV–Vis ...
متن کاملUV-Vis Spectrophotometry and Multivariate Calibration Method for Simultaneous Determination of Theophylline, Montelukast and Loratadine in Tablet Preparations and Spiked Human Plasma
Resolution of binary mixtures of theophylline (THEO), montelukast (MKST) and loratadine (LORA) with minimum sample pretreatment and without analyte separation has been successfully achieved by multivariate spectrophotometric calibration, together with partial least-squares (PLS-1), principal component regression (PCR) and hybrid linear analysis (HLA). Data of analysis were obtained from UV–Vis ...
متن کاملA Digital Sensor Simulator of the Pushbroom Offner Hyperspectral Imaging Spectrometer
Sensor simulators can be used in forecasting the imaging quality of a new hyperspectral imaging spectrometer, and generating simulated data for the development and validation of the data processing algorithms. This paper presents a novel digital sensor simulator for the pushbroom Offner hyperspectral imaging spectrometer, which is widely used in the hyperspectral remote sensing. Based on the im...
متن کاملImprovement of the Sciamachy Radiometric Calibration and Its Validation on Solar Irradiances in the Spectral Range from 240 to 2380 Nm
SCIAMACHY (SCanning Imaging Absorption spectroMeter for Atmospheric CHartographY) is part of the payload of ESA’s Environmental Satellite ENVISAT which was launched into a sun-synchronous polar orbit on 2002-03-01. First in-flight validation results already showed inconsistencies of the radiometric calibration of SCIAMACHY. Hence the on-ground calibration was thoroughly revised and correction f...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Cytometry. Part A : the journal of the International Society for Analytical Cytology
دوره 62 1 شماره
صفحات -
تاریخ انتشار 2004