The use of Roentgen stereophotogrammetry to study micromotion of orthopaedic implants

نویسندگان

  • Edward R. Valstar
  • Johan H.C. Reiber
  • Piet M. Rozing
چکیده

Roentgen stereophotogrammetry is the most accurate Roentgen technique for three-dimensional assessment of micromotion of orthopaedic implants. The reported accuracy of Roentgen Stereophotogrammetric Analysis (RSA) ranges between 0.05 and 0.5 mm for translations and between 0.15j and 1.15j for rotations. Because of the high accuracy of RSA, small patient groups are in general sufficient to study the effect on prosthetic fixation due to changes in implant design, addition of coatings, or new bone cements. By assessing micromotion of a prosthesis in a short-term (i.e. 2 years) clinical RSA study, a prediction can be made on the chance of long-term (i.e. 10 years) loosening of the prosthesis. Therefore, RSA is an important measurement tool to screen new developments in prosthetic design, and to prevent large groups of patients from being exposed to potentially inferior designs. In this article, the basics of the RSA technique are explained, and the importance of clinical RSA studies is illustrated with two examples of clinical RSA studies which RSA delivered very valuable information. Thereafter, two recent developments in RSA that have been implemented at Leiden University Medical Center are presented: digital automated measurements in RSA radiographs and model-based RSA. D 2002 Elsevier Science B.V. All rights reserved.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Digital Roentgen Stereophotogrammetry : Development , Validation , and Clinical Application

Contents 1 General introduction 9 2 RSA in practical steps 19 3 RSA of the Mallory-Head femoral stem without attached markers 33 4 Roentgen stereophotogrammetric analysis of metal-backed hemispherical cups without attached markers 49 5 Fast and accurate automated measurements in digitised stereophotogrammetric radiographs 59 6 Digital automated RSA compared to manually operated RSA 75 7 Model-b...

متن کامل

The Use of Radiostereometric Analysis in Fractures of the Distal Radius

Rami Madanat The use of radiostereometric analysis in fractures of the distal radius: From phantom models to clinical application Orthopaedic Research Unit, Department of Orthopaedic Surgery and Traumatology, University of Turku, Turku, Finland. Annales Universitatis Turkuensis, Medica-Odontologica, 2011, Turku, Finland. Radiostereometric analysis (RSA) is a highly accurate method for the measu...

متن کامل

Does Early Micromotion of Femoral Stem

Roentgen stereophotogrammetry was used to measure the migration of the centre of the femoral head in 84 cemented Lubinus SP I hip arthroplasties (58 primary operations, 26 revisions). Four to seven years later, seven femoral components had been revised because of painful loosening. These implants showed greater subsidence, medial migration and posterior migration during the first two postoperat...

متن کامل

Wrist-joint ligament length changes in flexion and deviation of the hand: an experimental study.

A method to study ligament-length patterns in situ with roentgen-stereophotogrammetry, using strings of glued tantalum markers, was developed. The method was tested against a bone-to-bone marking method in five carpal ligaments in three specimens, whereby the hand was moved through dorsopalmar flexion and radioulnar deviation. The "glued-string" marking method was found to be superior to the bo...

متن کامل

Aetna considers radiostereometric analysis for migration and wear of orthopedic implants and for all other indications (e.g., assessment of spinal fusion, evaluation of stability in lateral calcaneal lengthening osteotomies, and prediction of long‐term outcome in total hip

Background Radiostereometric analysis (RSA) has been used to determine migration and wear of orthopedic implants. Radiostereometry makes use of a cage with control marker and fiducial to calculate a three dimensional (3D) coordinate system. Spherical tantalum markers are inserted into the bone and implant to identify distinct points of measurement for each part of the skeleton and implant invol...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2002