Interventional repair of pseudoaneurysm of ascending aorta following prosthetic aortic valve replacement.
نویسندگان
چکیده
To cite: Harky A, Khosravi A, Colledge J, et al. BMJ Case Rep Published online: [please include Day Month Year] doi:10.1136/ bcr-2017-219196 DESCRIPTION Ascending aorta pseudoaneurysm is a high-risk complication post cardiac surgery. Although surgical repair is the conventional method of treatment, it is associated with a high mortality rate of 30% and a very poor prognosis. We report an old man aged 85 years who underwent elective biological aortic valve replacement for severe aortic valve stenosis and closure of left atrial appendage with AtriClip. Cardiopulmonary bypass was established with standard ascending aorta and right atrial cannulations. The aortic valve was replaced with 27 mm Hancock II type using 2/0 Ethibond pledgetted sutures in interrupted suture techniques. His
منابع مشابه
Pseudoaneurysm of the ascending aorta after aortic valve replacement that presented as a pulsatile chest wall mass.
We describe the case of a man incidentally found to have a pseudoaneurysm of the ascending aorta at the site of a previously (12 years ago) implanted metallic prosthetic aortic valve. Transthoracic echocardiography and computed tomography images demonstrate the pseudoaneurysm. The patient has undergone surgical repair with a good result.
متن کاملRepair of aortic regurgitation due to Takayasu arteritis.
BACKGROUND Prosthetic valve detachment after aortic valve replacement and pseudoaneurysm formation are the most important postoperative complications in patients with Takayasu arteritis with aortic regurgitation. We reviewed our experience of surgical treatment of aortic regurgitation in patients with Takayasu disease. METHODS Between November 1997 and September 2011, 11 patients (4 women and...
متن کاملBailout Endovascular Stent Grafting for an Ascending Aortic Pseudoaneurysm Using an Infrarenal Aortic Extension Cuff
We report successful thoracic endovascular repair of a pseudoaneurysm rupture in the ascending aorta using infrarenal endovascular devices after an aortic valve replacement. Complete exclusion of the pseudoaneurysm was achieved with no endoleak or postoperative complications. Despite limitations of the current technology, this endovascular technique was a relatively less invasive, feasible life...
متن کاملSurgical Repair of a Pseudoaneurysm of the Ascending Aorta after Previous Aortic Valve Replacement and Aneurysmorrhaphy
We report the case of a patient with a pseudoaneurysm of the ascending aorta. He was referred to our hospital because of chest pain and dyspnea. A preoperative diagnostic evaluation revealed a large pseudoaneurysm of the ascending aorta close to the proximal anastomotic site of the graft. During surgery, the pseudoaneurysm originated from an intimal defect in the aortic wall on the right side o...
متن کاملEndovascular repair of ascending aortic pseudoaneurysm.
We describe a complex case of ascending aortic pseudoaneurysm after open repair of ascending aortic aneurysm and aortic valve replacement. Although treatment was complicated due to intra-operative graft migration, the patient was successfully treated with endovascular technique.
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- BMJ case reports
دوره 2017 شماره
صفحات -
تاریخ انتشار 2017