An Improved FFR Design with a Ventilation Fan: CFD Simulation and Validation
نویسندگان
چکیده
This article presents an improved Filtering Facepiece Respirator (FFR) designed to increase the comfort of wearers during low-moderate work. The improved FFR aims to lower the deadspace temperature and CO2 level by an active ventilation fan. The reversing modeling is used to build the 3D geometric model of this FFR; the Computational Fluid Dynamics (CFD) simulation is then introduced to investigate the flow field. Based on the simulation result, the ventilation fan of the improved FFR can fit the flow field well when placed in the proper blowing orientation; streamlines from this fan show a cup-shape distribution and are perfectly matched to the shape of the FFR and human face when the fan blowing inward. In the deadspace of the improved FFR, the CO2 volume fraction is controlled by the optimized flow field. In addition, an experimental prototype of the improved FFR has been tested to validate the simulation. A wireless temperature sensor is used to detect the temperature variation inside the prototype FFR, deadspace temperature is lowered by 2 K compared to the normal FFR without a fan. An infrared camera (IRC) method is used to elucidate the temperature distribution on the prototype FFR's outside surface and the wearer's face, surface temperature is lowered notably. Both inside and outside temperature results from the simulation are in agreement with experimental results. Therefore, adding an inward-blowing fan on the outer surface of an N95 FFR is a feasible approach to reducing the deadspace CO2 concentration and improve temperature comfort.
منابع مشابه
Natural Ventilation: Analysis of Indoor Airflow in an Assumed Cubic Building with Opposite Openings by CFD Investigations
The natural ventilation is an easy way to exchange the indoor polluted warm air with outdoor fresh air. The wind power injects outdoor fresh air into the building. A good indoor air current and subsequently a proper exhaust depend on the openings’ conditions and their situations. A serious architectural question is under what conditions of the openings the wind-cross ventilation can be effectiv...
متن کاملCfd Simulation of Temperature Stratification for a Building Space: Validation and Sensitivity Analysis
Accurate and reliable CFD simulation of temperature stratification in indoor environment is needed for the design and evaluation of displacement ventilation in buildings. This paper presents a detailed and systematic evaluation of the capability of 3D steady RANS CFD simulations to predict the temperature stratification in a room. The evaluation is based on sensitivity analysis and validation w...
متن کاملMeasurement and Numerical Simulation of Air Velocity in a Tunnel-Ventilated Broiler House
A building needs to be designed for the whole period of its useful life according to its requirements. However, future climate predictions involve some uncertainty. Thus, several sustainable strategies of adaptation need to be incorporated after the initial design. In this sense, tunnel ventilation in broiler houses provides high air velocity values (2–3 m·s−1) at animal level to diminish their...
متن کاملAn example of verification , validation , and reporting of indoor environment CFD analyses ( RP - 1133 )
This paper illustrates a step-by-step process on how to use "The Manual for Verification, Validation, and Reporting of Indoor Environment CFD analyses" developed by ASHRAE. The details of the manual are further explained through an example of indoor environment modeling (an office with mechanical displacement ventilation). The verification, validation, and reporting do not have to be documented...
متن کاملComputational Fluid Dynamics Simulation and Experimental Validation of Hydraulic Performance of a Vertical Suspended API Pump (RESEARCH NOTE)
For a long period of time, design and manufacturing technology of high flow rated vertically suspended pumps (VSPs) which have an extensive applications in many industries such as water and wastewater, mining, petrochemical and oil and gas industries, used to be imported from European countries. For the first time in Iran's pump industry, with the support of Ministry of Petrochemical[ah1] and ...
متن کامل