Geometric distortion correction for echo planar images using nonrigid registration with spatially varying scale.
نویسندگان
چکیده
One method used to correct geometric and intensity distortions in echo planar images is to register them to undistorted images via nonrigid deformations. However, some areas in the echo planar images are more distorted than others, thus suggesting the use of deformations whose characteristics are adapted spatially. In this article, we incorporate into our previously developed registration algorithm a spatially varying scale mechanism, which adapts the local scale properties of the transformation by means of a scale map. To compute the scale map, a technique is proposed that relies on an estimate of the expected deformation field. This estimate is generated using knowledge of the physical processes that induce distortions in echo planar images. We evaluate the method of spatially varying scale on both simulated and real data. We find that, in comparison with our earlier method using fixed scale, our new method finds deformation fields that are smoother and finds them faster without sacrificing accuracy.
منابع مشابه
Concurrent correction of geometric distortion and motion using the map-slice-to-volume method in echo-planar imaging.
The accuracy of measuring voxel intensity changes between stimulus and rest images in fMRI echo-planar imaging (EPI) data is severely degraded in the presence of head motion. In addition, EPI is sensitive to susceptibility-induced geometric distortions. Head motion causes image shifts and associated field map changes that induce different geometric distortion at different time points. Conventio...
متن کاملCompensation of geometric distortion effects on intraoperative magnetic resonance imaging for enhanced visualization in image-guided neurosurgery.
OBJECTIVE Preoperative magnetic resonance imaging (MRI), functional MRI, diffusion tensor MRI, magnetic resonance spectroscopy, and positron-emission tomographic scans may be aligned to intraoperative MRI to enhance visualization and navigation during image-guided neurosurgery. However, several effects (both machine- and patient-induced distortions) lead to significant geometric distortion of i...
متن کاملConcurrent Geometric Distortion Correction in Mapping Slice-to-volume (MSV) Motion Correction of fMRI Time Series
D. Yeo, J. A. Fessler, B. Kim Electrical Engineering and Computer Science, University of Michigan, Ann Arbor, MI, United States, Radiology, University of Michigan Medical School, Ann Arbor, MI, United States Introduction: The accuracy of measuring voxel intensity changes between stimulus and rest images in fMRI echo-planar imaging (EPI) data, from which brain activation maps are computed, is se...
متن کاملImage distortion correction in fMRI: A quantitative evaluation.
A well-recognized problem with the echo-planar imaging (EPI) technique most commonly used for functional magnetic resonance imaging (fMRI) studies is geometric distortion caused by magnetic field inhomogeneity. This makes it difficult to achieve an accurate registration between a functional activation map calculated from an EPI time series and an undistorted, high resolution anatomical image. A...
متن کاملEpi Distortion Correction by Constrained Nonlinear Coregistration Improves Group Fmri
Introduction Because of its short volume acquisition time, echo planar imaging (EPI) has remained the method of choice for most fMRI studies. A well-known problem with EPI are geometric distortions caused by magnetic susceptibility inhomogeneities in the field of view. Especially in the frontal part of the brain, this can cause activation to appear at an offset along the phase encoding (PE) dir...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Magnetic resonance imaging
دوره 26 10 شماره
صفحات -
تاریخ انتشار 2008