Ceramic Femoral Components in Total Knee Arthroplasty - Two Year Follow-Up Results of an International Prospective Multi-Centre Study

نویسندگان

  • Philipp Bergschmidt
  • Rainer Bader
  • Dirk Ganzer
  • Christian Hauzeur
  • Christoph Lohmann
  • Wolfgang Rüther
  • Domenico Tigani
  • Nicola Rani
  • Fernando Lopez Prats
  • Claudio Zorzi
  • Vincenzo Madonna
  • Stefano Rigotti
  • Francesco Benazzo
  • Stefano Marco Paolo Rossi
  • Guenther Kundt
  • Hans Rudolf Bloch
  • Wolfram Mittelmeier
چکیده

BACKGROUND Total knee arthroplasty can be considered as a reliable surgical procedure with a good long-term clinical result. However, implant failure due to particle induced aseptic loosening as well as the aspect of hypersensitivity to metal ions still remains an emerging issue. METHODS The purpose of this prospective international multi-centre study was to evaluate the clinical and radiological outcomes and the reliability of the unconstrained Multigen Plus Total Knee System with a new BIOLOX® delta ceramic femoral component. Cemented total knee arthroplasty was performed on 108 patients (110 knees) at seven hospitals in three countries. Clinical and radiological evaluations were performed preoperatively, and after 3, 12 and 24 months postoperatively using the HSS-, WOMAC-, SF-36-score and standardised X-rays. RESULTS The mean preoperative HSS-Score amounted to 55.5 ± 11.5 points and improved significantly in all postoperative evaluations (85.7 ± 11.7 points at 24 months). Furthermore, improvements in WOMAC- and SF-36-score were evaluated as significant at all points of evaluation. Radiolucent lines around the femoral ceramic component at 24 months were found in four cases. Progression of radiolucent lines was not seen and no implant loosening was observed. During the 24 month follow-up eight patients underwent subsequent surgery due to reasons unrelated to the implant material. CONCLUSIONS The observed clinical and radiological results are encouraging for a long-term survival of the ceramic femoral component. Therefore, ceramic implants could be a promising solution not only for patients with allergies against metallic implant materials, but also for the osteoarthritic knee joint. Long-term follow-up is necessary to draw conclusions regarding the superiority of the ceramic knee implants concerning in vivo wear and long-term survivorship.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Hybrid total knee arthroplasty: 10- to 16-year follow-up.

A cementless femoral component may allow for a smaller surgical incision when a minimally invasive approach is used during primary total knee arthroplasty. Fixation by cement is the gold standard for total knee arthroplasty. The results of cementless total knee arthroplasty are mixed. Cementless femoral components have done well. Although some tibial components have performed well at long-term ...

متن کامل

First clinical study of a novel complete metal-free ceramic total knee replacement system

BACKGROUND The aim of the study was to evaluate the safety and efficacy of a novel metal-free ceramic total knee replacement system. METHODS Thirty-eight primary total knee arthroplasties (TKAs) were performed on 34 patients using the metal-free BPK-S ceramic total knee replacement system with both the femoral and tibial components of an alumina/zirconia ceramic composite. The clinical outcom...

متن کامل

Partial 2-Stage Revision in Chronic Hip Arthroplasty Infections: A Review

Background: Periprosthetic hip infections (PHIs) are troublesome complications of hip arthroplasties. The gold standard procedure for treating chronic PHI is a 2-stage approach. Recently, however, more conservative approaches have been developed to spare the osseointegrated components and avoid sequestra, bone loss, devascularization, and difficult reconstructions. The partial ...

متن کامل

Posterior cruciate-retaining, rotating-platform total knee arthroplasty: minimum 4-year follow-up study.

Rotating-platform, mobile-bearing total knee arthroplasty was initially developed using a posterior cruciate-sacrificing technique and design. Posterior cruciate-substituting and -retaining, rotating-platform total knee arthroplasty designs were developed later. The purpose of this study was to evaluate a minimum 4-year follow-up of total knee arthroplasty performed with a posterior cruciate-re...

متن کامل

How Much Bone Cement Is Utilized for Component Fixation in Primary Cemented Total Knee Arthroplasty?

Background: No scientific evidence exists regarding the amount of bone cement used and discarded in primarycemented Total knee arthroplasty (TKA). The aim of this study was to identify the exact amount of bone cement utilizedfor component fixation in primary TKA.Methods: In a prospective study carried out at five centers, 133 primary cemented TKAs were performed. One packof 40g Palacos bone cem...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 6  شماره 

صفحات  -

تاریخ انتشار 2012