Could Externalized St. Jude Medical Riata® Lead Be a Culture Medium of a Polymicrobial Endocarditis? A Clinical Case
نویسندگان
چکیده
We report the case of a man affected by polymicrobial endocarditis developed on a St. Jude Medical Riata lead with a malfunction because of the outsourcing of conductors. The patient was treated with antibiotic targeted therapy and showed different bacteria at the blood cultures and then underwent transvenous leads extraction. Vegetations were highlighted on the caval, atrial, and ventricular tracts of the Riata lead, but the cultures were all negative. The externalization of Riata lead may cause the malfunction but it could also promote bacterial colonies and vegetations. In conclusion, looking for early signs of infection is mandatory during Riata leads follow-up checks.
منابع مشابه
Externalized Conductor Cables in QuickSite Left Ventricular Pacing Lead and Riata Right Ventricular Lead in a Single Patient: A Common Problem With Silicone Insulation
QuickSite (St Jude Medical, Sylmar, CA, USA) is a silicone and polyurethane-insulated coronary sinus pacing lead. Riata lead (St Jude Medical, Sylmar, CA, USA) is a silicone insulated right ventricular shock lead. Recently, insulation breach of silicone based leads raised a huge concern. Fluoroscopic examination of these two leads in the same patient revealed externalization of these two leads....
متن کاملFluoroscopic investigation of Riata® transvenous defibrillator leads.
BACKGROUND Implantable cardioverter-defibrillator leads from Riata® family (St. Jude Medical Inc., Sylmar, CA, USA) have been recently recalled by Food and Drug Administration for concerns of a unique type of "inside-out" insulation failure leading to conductor externalization. The objective of this study was to evaluate the prevalence and predictors of conductor externalization in patients imp...
متن کاملCanadian Registry of Implantable Electronic Device Outcomes
An advisory related to the Riata and Riata ST leads was announced on November 28, 2011 by St. Jude Medical after these leads had been removed from the market the year before. This advisory described the possibility of conductors within the implantable cardioverter–defibrillator (ICD) lead becoming externalized because of an inside-out abrasion mechanism. This is a novel failure mechanism, not r...
متن کاملFluoroscopic screening of asymptomatic patients implanted with the recalled Riata lead family.
BACKGROUND The Food and Drug Administration recently issued a class I recall of the St. Jude Medical Riata implantable cardioverter-defibrillator lead presumably because of increased risk of electric failure and mechanical separation via inside-out abrasion. We sought to examine the incidence and time dependence of inside-out abrasion in asymptomatic patients implanted with the Riata lead. ME...
متن کاملSuccessful detection of a high-energy electrical short circuit and a “rescue” shock using a novel automatic shocking-vector adjustment algorithm
Introduction A high-voltage (HV) electrical short circuit can be a critical electrical failure in an implantable cardioverter-defibrillator (ICD) system because of the failed delivery of appropriate shocks against fatal arrhythmia. The Food and Drug Administration has classified the St Jude Medical Riata family of ICD leads (St Jude Medical, St Paul, MN) as a class I recall since 2011 because o...