Corneal and scleral distensibility ratio on enucleated human eyes.

نویسندگان

  • R D Richards
  • P G Tittel
چکیده

The rigidity of the cornea and sclera was measured on ten enucleated human eyes by means of the distensibility ratio test. The eyes were obtained from the Medical Eye Bank of Maryland with the donor age ranging from 63 to 86 years. The time of anterior-posterior and equatorial measurements varied from 2 to 32 hours after enucleation. Changes in distensibility were recorded with a circumference gauge when pressure was elevated over a 100 mm. Hg pressure span. Scleral distensibility was greatest when a pressure change from 20 to 30 mm. Hg was recorded and decreased exponentially until approximately the 90 mm. Hg pressure level. Depending on the time elapsed after enucleatidn, the data on corneal distensibility was a curve of an S-shape pattern with maximum and minimum values. Maximum was recorded near the 50 mm. Hg level on a freshly enucleated eye. The maximum value increased and shifted toward lower pressure levels as time between enucleation and measurement was prolonged. In a test taken 32 hours after enucleation the maximum value was recorded at the initial pressure change from 20 to 30 mm. Hg. At this time interval the S-shape pattern of the curve was absent and the distensibility decreased uniformly as pressure was elevated. A statistical evaluation for the scleral part of these eyes showed no significant deviation. The characteristic of the corneal distensibility curve, however, showed clearly that the comeal distensibility was a function of two variables, namely age of donor and time elapsed after enucleation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

CO2 laser-assisted sclerectomy surgery part I: concept and experimental models.

PURPOSE To evaluate the safety and performance of a second-generation device for CO2 laser-assisted sclerectomy surgery system in experimental models. MATERIALS AND METHODS Laser-assisted deep sclerectomy using a modified CO2 laser system (OT-134-"IOPtiMate"; IOPtima Ltd, Israel) was performed in 3 experimental models: enucleated pig eyes, human cadaver eyes, and live rabbit eyes. A half-thic...

متن کامل

بررسی اثر قطره هوماتروپین 2% بر روی توپوگرافی قرنیه

 ABSTRACT The purpose of this study was the evaluation of cycloplegic effect of homatropine 2% on central corneal curvature and power. 43 volunteers who participated in the study were examined. Thirty-nine of them (28 men and 11 women) which had normal eyes with visual acuity of 20/20 and a mean age of 29.6 ± 6.7 years were selected. Then corneal topography was performed on both eyes. After per...

متن کامل

Scleral Thickness in Human Eyes

PURPOSE To obtain information about scleral thickness in different ocular regions and its associations. METHODS The histomorphometric study included 238 human globes which had been enucleated because of choroidal melanomas or due to secondary angle-closure glaucoma. Using light microscopy, anterior-posterior pupil-optic nerve sections were measured. RESULTS In the non-axially elongated grou...

متن کامل

بررسی تغییرات توپوگرافیک قرنیه بعد از اعمال جراحی اسکرال با کلینگ و ویترکتومی

To investigale the topographic changes in the cornea after scleral buckling and vitrectommy. A prospective study was conducted. Thses changes were analyzed based on the type of surgical procedures performed. Design of this study was observational prospective case series. 49 eyes from 48 patients were stratified into four groups based on the type of surgical procedures performed. 10 un...

متن کامل

Central corneal thickness and thickness of the lamina cribrosa in human eyes.

PURPOSE Since central corneal thickness may inversely influence the amount and rate of progression of glaucomatous optic nerve damage and because lamina cribrosa thickness may be of importance in susceptibility to glaucoma, it was the purpose of the present study to evaluate whether central corneal thickness is related to lamina cribrosa thickness. METHODS The histomorphometric study included...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Investigative ophthalmology

دوره 12 2  شماره 

صفحات  -

تاریخ انتشار 1973