Safe and sensible preprocessing and baseline correction of pupil-size data

نویسندگان

  • Sebastiaan Mathôt
  • Jasper Fabius
  • Elle Van Heusden
  • Stefan Van der Stigchel
چکیده

Measurement of pupil size (pupillometry) has recently gained renewed interest from psychologists, but there is little agreement on how pupil-size data is best analyzed. Here we focus on one aspect of pupillometric analyses: baseline correction, i.e., analyzing changes in pupil size relative to a baseline period. Baseline correction is useful in experiments that investigate the effect of some experimental manipulation on pupil size. In such experiments, baseline correction improves statistical power by taking into account random fluctuations in pupil size over time. However, we show that baseline correction can also distort data if unrealistically small pupil sizes are recorded during the baseline period, which can easily occur due to eye blinks, data loss, or other distortions. Divisive baseline correction (corrected pupil size = pupil size/baseline) is affected more strongly by such distortions than subtractive baseline correction (corrected pupil size = pupil size - baseline). We discuss the role of baseline correction as a part of preprocessing of pupillometric data, and make five recommendations: (1) before baseline correction, perform data preprocessing to mark missing and invalid data, but assume that some distortions will remain in the data; (2) use subtractive baseline correction; (3) visually compare your corrected and uncorrected data; (4) be wary of pupil-size effects that emerge faster than the latency of the pupillary response allows (within ±220 ms after the manipulation that induces the effect); and (5) remove trials on which baseline pupil size is unrealistically small (indicative of blinks and other distortions).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Multi-objective optimization for an automated and simultaneous phase and baseline correction of NMR spectral data.

Spectral data preprocessing is an integral and sometimes inevitable part of chemometric analyses. For Nuclear Magnetic Resonance (NMR) spectra a possible first preprocessing step is a phase correction which is applied to the Fourier transformed free induction decay (FID) signal. This preprocessing step can be followed by a separate baseline correction step. Especially if series of high-resoluti...

متن کامل

Effects of latanoprost and pilocarpine combination on the intraocular pressure and pupil size of normal rabbits

The aim of this study was to determine the combination effect of latanoprost and pilocarpine on theintraocular pressure and pupil size in normal rabbits. In this study, 18 rabbits were randomized to threegroups of 6 animals each. The right eyes of rabbits in group 1 were treated topically with latanoprost, ingroup 2 with pilocarpine and in group 3 with latanoprost and pilocarpine. The left eyes...

متن کامل

Benefits from the correction of vitamin D deficiency in patients with pulmonary hypertension

Background: Vitamin D (Vit D) is linked to various conditions including musculoskeletal, metabolic and   cardiopulmonary diseases. However, it is not clear whether correction of vit D deficiency exerts any beneficial effect in patients with pulmonary hypertension. Methods: This study was a prospective uncontrolled longitudinal study. Patients with pulmonary hypertension and vit D d...

متن کامل

جاسازی خط ویژگی وزن‌دار برای استخراج ویژگی تصاویر ابرطیفی

One of the most preprocessing steps before the classification of hyperspectral images is supervised feature extraction. Because obtaining the training samples is hard and time consuming, the number of available training samples is limited. We propose a supervised feature extraction method in this paper that is efficient in small sample size situation. The proposed method, which is called weight...

متن کامل

Discrimination of Golab apple storage time using acoustic impulse response and LDA and QDA discriminant analysis techniques

ABSTRACT- Firmness is one of the most important quality indicators for apple fruits, which is highly correlated with the storage time. The acoustic impulse response technique is one of the most commonly used nondestructive detection methods for evaluating apple firmness. This paper presents a non-destructive method for classification of Iranian apple (Malus domestica Borkh. cv. Golab) according...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 50  شماره 

صفحات  -

تاریخ انتشار 2018