The Physics Program at Mami-c

نویسنده

  • Patrick Achenbach
چکیده

In February 2007, the fourth stage of the Mainz Microtron, MAMI-C, started operations with a first experiment. The new Harmonic Double-Sided Microtron delivers an electron beam with energies up to 1.5GeV while preserving the excellent beam quality of the previous stages. The experimental program at MAMI is focused on studies of the hadron structure in the domain of non-perturbative QCD. In this paper, a few prominent selections of the extensive physics program at MAMI-C will be presented. 1 The new 1.5GeV Harmonic Double-Sided Microtron as the Fourth Stage of MAMI The Mainz Microtron MAMI is a unique facility in Europe to study the hadron structure with the electromagnetic probe at small momentum transfers. MAMI comprises a cascade of three race-track microtrons (RTM), delivering since 1991 a high-quality 855MeV, 100 μA cw-electron beam, which was energy upgraded by a fourth stage, MAMI-C, in recent years. Realizing the fourth stage as another RTM was evidently impossible: the two 180◦-bending magnets would have had a weight of approx. 2× 2000 tons for an end-point energy of 1.5GeV. However, for the next higher polytron configuration, the Double-Sided Microtron (DSM), this weight is reduced by a factor of four. By operating at 4.90GHz, the first harmonic of the fundamental 2.45GHz radio-frequency (rf), the necessary coherent energy gain per turn for the two normal conducting linacs is reduced to get a moderate power consumption [1]. For achieving a simple transverse optics the strong vertical fringe field defocusing of the four 90◦-bending magnets is compensated by a clam-shell field geometry. In this configuration uncritical longitudinal beam

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

the Structure of the Nucleon

In February 2007, the fourth stage of the Mainz Microtron, MAMI-C, started operations with a first experiment. The new Harmonic Double-Sided Microtron delivers an electron beam with energies up to 1.5GeV while preserving the excellent beam quality of the previous stages. The experimental program at MAMI is focused on studies of the hadron structure in the domain of non-perturbative QCD. In this...

متن کامل

The new 1 . 5 GeV Harmonic Double - Sided Microtron

In February 2007, the fourth stage of the Mainz Microtron, MAMI-C, started operations with a first experiment. The new Harmonic Double-Sided Microtron delivers an electron beam with energies up to 1.5GeV while preserving the excellent beam quality of the previous stages. The experimental program at MAMI is focused on studies of the hadron structure in the domain of non-perturbative QCD. In this...

متن کامل

Recent Status of the Mami-c Accelerator and First Experiences with the Energy Upgrade towards 1.6 Gev*

The University of Mainz’ institute for nuclear physics is operating the microtron cascade MAMI (Mainzer Mikrotron) since the late 1970ies. The microtron delivers a cw electron beam to users of the hadron physics community. The recent, fourth stage MAMI-C having a design energy of 1.5 GeV is operated since 2006 [1]. This article deals with the recent developments and operational experiences of M...

متن کامل

2 00 5 A luminosity monitor for the A 4 parity violation experiment at MAMI

A water Cherenkov luminosity monitor system with associated electronics has been developed for the A4 parity violation experiment at MAMI. The detector system measures the luminosity of the hydrogen target hit by the MAMI electron beam and monitors the stability of the liquid hydrogen target. Both is required for the precise study of the count rate asymmetries in the scattering of longitudinall...

متن کامل

Clinical Medical Physicist Training Program at Reza Radiotherapy and Oncology Centre (RROC)

Introduction: It has been shown that there is a strong correlation between training and improving the Radiation Oncology Medical Physicist (ROMP) and an Oncology Department Quality Management plans. The Reza Radiotherapy and Oncology Centre (RROC) beside of its development plan, has recently implemented a comprehensive in-site training plan based on ROMPs abilities and the Depa...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008