Corneal endothelial cells' protection against thermal injury: influence of ophthalmic viscoelastic substances in experimental study on rabbits.

نویسندگان

  • P Jurowski
  • R Gos
  • G Owczarek
  • G Z Gralewicz
چکیده

PURPOSE To quantify the maximal level of temperature and the time the maximal temperature is achieved and correlate the temperature parameters to the mean rate of endothelial cell loss after standardized ultrasound delivery assisted with four viscoelastic substances or different temperature of balanced salt solution (BSS). METHODS Thirty rabbits (60 eyes) were divided into six groups in which different viscoelastic substances or different temperature of BSS were used: Group 1, Viscoat; 2, Provisc; 3, soft shell technique; 4, Celoftal; 5, BSS 22 C; and 6, BSS 4 C. The same parameters of ultrasound energy were delivered by standard phaco tip introduced into pupillary plane. Thermocamera was employed for measurements of temperature parameters. Endothelium cell count was measured before surgery and 1 month postoperatively. RESULTS Maximal level of temperature was measured as follows: Group 5, 27.85 0.52 C; Group 2, 27.75 0.54 C; Group 3, 27.74 0.46 C; Group 4, 27.25 0.60 C; Group 6, 26.81 0.34 C; Group 1, 26.52 0.48 C (p<0.05). The time the maximal temperature is achieved was statistically shorter in Groups 5 and 6: 4 seconds, 5 seconds, respectively, p<0.0001, as compared with Group 2 (30 seconds), Group 3 (40 seconds), Group 1 (45 seconds), and Group 4 (50 seconds). The mean rate of endothelial cell loss was calculated as follows: Group 1, 4.35%2.55%; Group 2, 8.43%5.2%; Group 3, 6.25%4.20%; Group 4, 6.53%4.65%; Group 5, 14.3%3.85%; and Group 6, 8.78%4.45%. CONCLUSIONS Viscoelastic substances offer different levels of endothelial cell protection against temperature increase during phacoemulsification. The mean rate of endothelial cell loss correlates with the time the maximal temperature is achieved rather than with the value of maximal level of temperature. This implicates that surgical strategy should consider the choice of the most effective viscoelastic substances, particularly in difficult cases, e.g., hard nucleus, shallow anterior chamber, primary endothelial abnormality.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The influence of viscoelastic substances on the corneal endothelium during cataract surgery by phacoemulsification.

PURPOSE To compare the ability of different ophthalmic viscoelastic devices to protect the corneal endothelium following in-the-bag phacoemulsification with posterior chamber intraocular lens (IOL) implantation. MATERIAL & METHODS We studied 50 patients with soft to moderately dense (Grade 1-3) cataract and corneal endothelial cell density of >2000 cells/mm2. The corneal response to surgery w...

متن کامل

Effects of hyaluronic acid on the polymorphonuclear leukocyte (PMN) release of active oxygen and protection of bovine corneal endothelial cells from activated PMNs.

The goal of this study was to evaluate the function of hyaluronic acid (HA) on the active oxygen release from polymorphonuclear leukocytes (PMNs) and the protective effect of bovine corneal endothelial cells (BCEC) from activated PMNs. We used HA with three different molecular weights (MW 700,000, 2,000,000, and 4,000,000) and five different concentrations (0, 0.1, 1, 2, and 3 mg/ml). We evalua...

متن کامل

Changes in corneal endothelium cell characteristics after cataract surgery with and without use of viscoelastic substances during intraocular lens implantation

PURPOSE To evaluate whether the use of balanced salt solution (BSS) or an ophthalmic viscoelastic device (OVD) during hydrophilic acrylic intraocular lens (IOL) implantation variously impacts corneal endothelial cell characteristics in eyes undergoing uneventful phacoemulsifications. METHODS Prospective nonrandomized observational clinical trial. Patients were assigned either to the BSS plus(...

متن کامل

A clinical comparison between DisCoVisc and 2% hydroxypropylmethylcellulose in phacoemulsification: a fellow eye study

OBJECTIVE This study sought to compare the effects and outcomes of two ophthalmic viscosurgical devices, 1.6% hyaluronic acid/4.0% chondroitin sulfate and 2.0% hydroxypropylmethylcellulose, during phacoemulsification. METHODS This prospective, randomized clinical trial comprised 78 eyes (39 patients) that received phacoemulsification performed by the same surgeon using a standardized techniqu...

متن کامل

Surgical Applications and Complications

December, 2003 DOS Times Vol.9, No.6 Background Viscoelastic substances are solutions with dual properties; they act as viscous liquids as well as elastic solids or gels. The ideal viscoelastic substance in ophthalmology should be viscous enough to prevent collapse of the anterior chamber at rest, yet liquid enough to be injected precisely through a small cannula. It should be elastic or shock ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European journal of ophthalmology

دوره 15 6  شماره 

صفحات  -

تاریخ انتشار 2005