Effects of prosthesis materials and prosthesis splinting on peri-implant bone stress around implants in poor-quality bone: a numeric analysis.
نویسندگان
چکیده
PURPOSE A 3-dimensional finite element model consisting of a bone block and 2 simulated premolar crowns supported by 2 adjacent cylindric implants without immediately surrounding cortical bone was generated and used to investigate the effects of prosthesis materials and prosthesis splinting on the peri-implant bone stress under static loads. MATERIALS AND METHODS The peri-implant maximum equivalent bone stress (von Mises [VM] stress) was evaluated when a vertical or a horizontal load of 1 N was applied to the center of a single resin, gold alloy, or porcelain crown, nonsplinted or splinted to the adjacent crown. RESULTS The numeric results indicated that: (1) in a single crown, no significant difference could be found in the maximum VM stress between different materials for both vertical and horizontal loading; (2) splinting the crowns reduced the maximum VM stress induced by the horizontal load, and the maximum VM stress increased about 14% for the horizontal loading when the restorative material was changed from gold alloy or porcelain to resin. DISCUSSION Under the condition of this study's analysis, prosthesis materials of a single crown have insignificant effects on the peri-implant bone stress. Splinting the crowns reduced the peri-implant bone stress under horizontal load, and gold alloy and porcelain each demonstrated less peri-implant bone stress than resin in the splinted crown situation under static horizontal load. CONCLUSION Splinting the crowns of adjacent implants with relatively stiff restorative materials is recommended for implants surrounded by poor-quality bone.
منابع مشابه
تعیین توزیع تنش استخوان اطراف ایمپلنتهای فک پایین در طرحهای مختلف پروتز به هنگام Mandibular- Flexure
Statement of Problem: In the treatment of edentulous patients with implant supported fixed partial dentures several factors such as implant numbers, implant position, superstructure pattern and cantilever length must be considered. Mandibular flexture in function exerts forces in peri-implant bone, however this phenomenon has received little attention. Purpose: The goal of this finite element a...
متن کاملEffect of Coating Materials on the Fatigue Behavior of Hip Implants: A Three-dimensional Finite Element Analysis
This study aims to validate, using finite element analysis (FEA), the design concept by comparing the fatigue behavior of hip implant stems coated with composite (carbon/PEEK) and polymeric (PEEK) coating materials corresponding to different human activities: standing up, normal walking and climbing stairs under dynamic loadings to find out which of all these models have a better performance in...
متن کاملتعیین توزیع تنش و کرنش استخوان اطراف ایمپلنت در طرح All-on-4 به روش آنالیز اجزای محدود
Background and Aims: The All-on-4 design with its significant advantages is an appropriate model in reconstruction of edentulous mandible. Evaluation of stress and strain distribution in this model is necessary for better judgment. The purpose of this FEA study was to measure stress and strain distribution on peri-implant bone in All-on-4 design in edentulous mandible. Materials and Methods: Th...
متن کاملRadiographic Comparison of Crestal Bone Loss Around Two Implant Systems with Different Surface Roughness: A Retrospective Study
Background and Aim: This retrospective study aimed to investigate the effects of surface roughness and implant body design on the amount of crestal bone loss around implant. Materials and Methods: In this retrospective study, dental records of 87 patients who received 139 implants were evaluated. The ITI group received 63 implants with moderate roughness, while the DIO group received 76 implan...
متن کاملمطالعه تنشهای اطراف ایمپلنت به روش اجزای محدود در بریجهای با ساپورت دندان/ایمپلنت در شرایط اتصال سخت و غیرسخت در پروتزهای سمان شونده
Background and Aims: Freestanding fixed partial prosthesis is considered the first choice whenever possible. However, anatomical limitations for implants and other reasons may create situation in which it would be preferable to connect the implants to teeth. A biomechanical dilemma in a tooth/implant-supported system comes from dissimilar mobility. This disparity cause the bridge to function as...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The International journal of oral & maxillofacial implants
دوره 17 2 شماره
صفحات -
تاریخ انتشار 2002