A multiprobe miniature thermistor system for the measurement of temperature profiles

نویسندگان

  • Noam Lior
  • Jacques Leibovitz
چکیده

A new instrument for the determination of fine temperature profiles in hot, corrosive, electrically conductive, unsteady two-phase fluid systems under vacuum or pressure is described. It features simultaneous measurement of temperatures at close locations, by a column of miniature (0.25 mm diam) thermistors mounted at the tips of supporting hypodermic tubes, and streamlined design that minimizes hydrodynamic and thermal disturbances at the measured locations. Some of the techniques used in the construction, such as the welding, insulation, and handling of fine wires (0.025 mm diam), are of interest in many other applications. The instrument has been used to measure temperature distributions with an accuracy of +0.02°C in a model of a flash-evaporator stage used for the desalination of saline water, and thus provided new and quantitatively significant data about the process.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A New Structure for Direct Measurement of Temperature Based on Negative Temperature Coefficient Thermistor and Adaptive Neuro-fuzzy Inference System

Thermistors are very commonly used for narrow temperature-range high-resolution applications, such as in medicine, calorimetry, and near ambient temperature measurements. In particular, Negative Temperature Coefficient (NTC) thermistor is very inexpensive and highly sensitive, whose sensing temperature range and sensitivity are highly limited due to the intrinsic nonlinearity and self-heating p...

متن کامل

THE ACCURACY OF MIiIATURE BEAD THERMISTORS IN THE MEASUREMENT OF UPPER AIR TEMPERATURE

A laboratory study was made of the errors of miniature bead thermistors of 5, 10, and 15 mils nominal diameter when used for the measurement of atmospheric temperature. Although the study was primarily concerned with the errors of the thermistors when used in Meteorological rocket soundings between about 70 km and 30 km altitude the results are also valid for other applications of these thermis...

متن کامل

Improved accuracy and precision of thermodilution cardiac output measurement using a dual thermistor catheter system.

OBJECTIVES To assess whether thermodilution cardiac output determination based on measurement of injectate temperature in vivo leads to more accurate and precise estimates and to study the influence of chilled injectate on test performance. BACKGROUND Cardiac output measurement via right heart catheterization is used extensively for hemodynamic evaluation in a variety of diagnostic, periopera...

متن کامل

Development of multiple velocity and temperature probe sets for ventilated spaces

Development of a low-cost computer-based system for multi-point measurement of velocity and temperature has been completed. The principle is based on hot-wire anemometry. A typical probe consists of a cold thermistor for flow temperature detection and a hot thermistor for flow velocity detection. The later is selfheated by a thermal potentiometer circuit. The change in resistance of the thermis...

متن کامل

Calibration of Buffer-less system for thermistor temperature measurement

This paper presents a temperature measurement system without the input buffer. A voltage follower or a buffer is required to minimize the influence of the ADC input impedance in the thermistor temperature measurement system. In such system, a high performance operational amplifier is usually required to prevent the noise and distortion due to the additional circuit. Negative power is also neces...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012