Dose Distributions in Simulated Electron Radiotherapy with Intraoral Cones Using Treatment Planning System

نویسندگان

  • Tomohiro Shimozato
  • Kuniyasu Okudaira
  • T. Shimozato
  • K. Okudaira
چکیده

Aim: This study aims to evaluate the difference between depth data from an intraoral cone and a conventional irradiation tube calculated using a treatment planning system (TPS), and that measured using an intraoral cone for electron radiotherapy. Background: A TPS is only compatible with conventional irradiation tubes. However, such systems are not suitable for determining dose distributions when a special cone is employed. Materials and Methods: Dose distributions were calculated using the beam data for mounted intraoral cones using a TPS. Then, the dose distribution by field size was calculated for a low-melting-point lead alloy using the beam data for a mounted conventional tube. The calculated data were evaluated against the measured intraoral-cone depth data based on the dose and depth differences. Results: The calculated data for the intraoral cone case did not match the measured data. However, the depth data obtained considering the field size determined for the lead alloy using the conventional tube were close to the measured values for the intraoral cone case. The difference in the depth at which the absorbed dose was 50% of the maximum value of the percentage depth dose was less than ±4 mm for the generalized Gaussian pencil beam convolution algorithm and less than ±1 mm for the electron Monte Carlo algorithm. Conclusion: It was found that the measured and calculated dose distributions were in agreement, especially when then electron Monte Carlo algorithm was used. Thus, the TPS can be employed to determine dose distributions for intraoral cone applications.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of the electron energy fluence and angular distributions from a clinical accelerator. A BEAMnrc Monte Carlo study

Background: Understanding of the incident electron energy and angular distributions from clinical electron accelerators (linacs) is important for dosimetry and treatment planning. The most important goals of this study were to evaluate the energy fluence and angular distributions of electron beams from a Neptun 10PC linac using the Monte Carlo (MC) code. Materials and Methods: The lina...

متن کامل

Investigating the effects of different kernels used for CT image reconstruction on dose distributions in treatment planning of kidney cancer radiotherapy

Introduction: The quality of CT images used for treatment planning of cancer patients is an important issue in accurate outlining of the tumor volume and organs at risk. Different kernels in CT scanner systems are available for improving the image quality. Applying these kernels  on   CT  images  will  change   the   CT  numbers  and  electron   density   of   tissues, conse...

متن کامل

Discrepancies in dose distributions due to age- dependent bone electron density in pediatric MRI-only treatment planning: A Monte Carlo study

Introduction: MRI-only treatment planning (TP) can be advantageous in paediatric radiotherapy. However, electron density extraction is necessary for dose calculation. Normally, after bone segmentation, a bulk density is assigned. However, the variation of bone bulk density in patients makes the creation of pseudo CTs challenging. This study aims to assess the effects of bone den...

متن کامل

Optimization of Beam Orientation and Weight in Radiotherapy Treatment Planning using a Genetic Algorithm

Introduction: The selection of suitable beam angles and weights in external-beam radiotherapy is at present generally based upon the experience of the planner. Therefore, automated selection of beam angles and weights in forward-planned radiotherapy will be beneficial. Material and Methods: In this work, an efficient method is presented within the MATLAB environment to investigate how to improv...

متن کامل

Evaluation of Dose Calculation Accuracy of Isogray Treatment Planning System in Craniospinal Radiotherapy

Introduction: Craniospinal radiotherapy is a therapeutic technique for central nervous system (CNS) tumors, which requires meticulous attention to technique and dosimetry.Treatment planning system (TPS) is one of the main equipment in radiotherapy; therefore, the evaluation of its accuracy is essential for dose calculation. The present study evaluates the validity of Isogray TPS in craniospinal...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2017