Performance characteristics of six third-generation assays for thyroid-stimulating hormone.
نویسندگان
چکیده
BACKGROUND Thyroid-stimulating hormone (TSH) is used to detect primary hypo- and hyperthyroidism. Current guidelines for TSH assays recommend a functional sensitivity of < or =0.02 mIU/L. The protocol for determining the functional sensitivity of TSH assays specifies analyses of serum samples with two reagent lots over a 6- to 8-week period. METHODS We determined the functional sensitivities of the Access 2, ADVIA Centaur, ARCHITECT i2000, E170, IMMULITE 2000, and Vitros ECi automated methods, using seven serum pools and two reagent lots for each method. RESULTS The observed functional sensitivities were as follows: Access 2, <0.020 mIU/L; ADVIA Centaur, 0.039 mIU/L; ARCHITECT i2000, <0.005 mIU/L; Elecsys E170, 0.011 mIU/L; IMMULITE 2000, 0.014 mIU/L; Vitros ECi, 0.004 mIU/L. However, there were large differences between some method means for the seven serum pools. For the pool with the lowest TSH concentration, mean results were as follows: Access 2, 0.0203 mIU/L; ADVIA Centaur, 0.0085 mIU/L; ARCHITECT i2000, 0.0049 mIU/L; E170, 0.0098 mIU/L; IMMULITE 2000, 0.0077 mIU/L; Vitros ECi, 0.0014 mIU/L. Method-comparison studies using samples with TSH concentrations >0.2 mIU/L also showed method differences. The ARCHITECT i2000 method was the most precise at low TSH concentrations. CONCLUSIONS TSH methods do not provide comparable results for serum pools with TSH concentrations <0.2 mIU/L or for patient results across the analytic measurement range. Further investigation into the cause of these differences and additional harmonization efforts are required.
منابع مشابه
THYROID FUNCTION TESTS Thyroid Stimulating Hormone (TSH): The thyroid stimulating hormone (TSH) assay measures the concentration of thyroid stimulating hormone in the serum. TSH assays
The thyroid stimulating hormone (TSH) assay measures the concentration of thyroid stimulating hormone in the serum. TSH assays have been classified by "generation" based on the functional sensitivity of the assay, i.e., the lowest concentration at which the assay is able to maintain an inter-assay precision, expressed in terms of percent coefficient of variation (%CV), of 20% or less. Virtually...
متن کاملTwo sensitive immunometric assays for serum thyroid stimulating hormone evaluated.
This study was conducted to evaluate the analytical performance (functional sensitivity, reproducibility, parallelism, and accuracy) of two recent commercial kits marketed as third generation immunometric assays for measuring serum thyroid stimulating hormone (TSH). One assay is automated; the other is manual. Accuracy by method comparisons was evaluated using 86 patient samples assayed by an e...
متن کاملPersistent Graves’ hyperthyroidism despite rapid negative conversion of thyroid-stimulating hormone-binding inhibitory immunoglobulin assay results: a case report
BACKGROUND Graves' disease is an autoimmune thyroid disorder characterized by hyperthyroidism, and patients exhibit thyroid-stimulating hormone receptor antibody. The major methods of measuring circulating thyroid-stimulating hormone receptor antibody include the thyroid-stimulating hormone-binding inhibitory immunoglobulin assays. Although the diagnostic accuracy of these assays has been impro...
متن کاملThyroid-stimulating hormone receptor antibody assays: recommendation for correct interpretation of results in Graves disease.
In Graves disease, the clinical uses of thyrotropin receptor [thyroidstimulating hormone receptor (TSH-R)] antibody (TRAb) measurements have been reported in the Thyroid Guidelines of the American Thyroid Association (1 ). First, TRAb measurements are used to investigate the etiology of hyperthyroidism when the diagnosis is not clinically obvious; second, a declining TRAb concentration during l...
متن کاملChemiluminescent third-generation assay (Amerlite TSH-30) of thyroid-stimulating hormone in serum or plasma assessed.
We assessed the laboratory performance and clinical utility of a new commercial third-generation assay of thyroid-stimulating hormone (TSH), Amerlite TSH-30. The interassay CV was 6% at TSH concentrations of approximately 0.08 mIU/L, and the analytical and functional detection limits of the assay were 0.005 and 0.0125 mIU/L, respectively. Although the assay recovered approximately 96% of TSH In...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 50 12 شماره
صفحات -
تاریخ انتشار 2004