Optimization of n TOF-EAR2 using FLUKA
نویسندگان
چکیده
In 2014 a new vertical flight path was installed at the neutron time-of-flight facility, n TOF, at CERN. The beam line optimization of this second experimental area (EAR2) was performed by FLUKA simulations with a detailed model of the facility, including the spallation target, neutron beam line, magnet, collimators and beam dump. The beam profile as well as neutron and gamma fluxes were calculated at the measurement position, 150 cm from the exit of the second collimator. The design of the collimator system was optimized taking into account the shape of the beam, the neutron flux and the background. The effect of the background of each studied configuration was evaluated from the response of a C6D6 detector at the measurement position. The design of the beam dump was modified according to each configuration to reduce the backscattered radiation. Among the studied configurations, a final collimator with a conical closing aperture was found to be the best compromise between a high flux and low background at the experimental station. By scoring the neutron flux at the measurement position and taking the air and windows at the nominal sample position into account, the neutron beam has a radius of 2.5 cm and the outside background is three orders of magnitude lower than the maximum flux. The ratio between background and maximum flux is similar to that in the first experimental area (EAR1), but the maximum flux in EAR2 is 30 to 50 times higher than in EAR1 for neutron energies between 100 eV and 30 keV, respectively.
منابع مشابه
Ear2 deletion causes early memory and learning deficits in APP/PS1 mice.
To assess the consequences of locus ceruleus (LC) degeneration and subsequent noradrenaline (NA) deficiency in early Alzheimer's disease (AD), mice overexpressing mutant amyloid precursor protein and presenilin-1 (APP/PS1) were crossed with Ear2(-/-) mice that have a severe loss of LC neurons projecting to the hippocampus and neocortex. Testing spatial memory and hippocampal long-term potentiat...
متن کاملEvaluation of Electron Specific Absorbed Fractions in Organs of Digimouse Voxel Phantom Using Monte Carlo Simulation Code FLUKA
Background: For preclinical evaluations of radiopharmaceuticals, most studies are carried out on mice. Values of electron specific absorbed fractions (SAF) have had vital role in the assessment of absorbed dose. In past studies, electron specific absorbed fractions were given for limited source target pairs using older reports of human organ compositions.Objective: Electron specific absorbed fr...
متن کاملEstimation of Photon Specific Absorbed Fractions in Digimouse Voxel Phantom using Monte Carlo Simulation Code FLUKA
Background: Most preclinical studies are carried out on mice. For internal dose assessment of a mouse, specific absorbed fraction (SAF) values play an important role. In most studies, SAF values are estimated using older standard human organ compositions and values for limited source target pairs.Objective: SAF values for monoenergetic photons of energies 15, 50, 100, 500, 1000 and 4000 keV...
متن کاملSimulation of Experimental Background Using Fluka
In November 1997, Experiment T423 began acquiring data with the intentions of understanding the energy spectra of high-energy neutrons generated in the interaction of electrons with lead. The following describes a series of FLUKA simulations studying (1) particle yields in the absence of all background; (2) the background caused from scattering in the room; (3) the effects of the thick lead shi...
متن کاملEvaluation of Lung Density and Its Dosimetric Impact on Lung Cancer Radiotherapy: A Simulation Study
Background: The dosimetric parameters required in lung cancer radiation therapy are taken from a homogeneous water phantom; however, during treatment, the expected results are being affected because of its inhomogeneity. Therefore, it becomes necessary to quantify these deviations.Objective: The present study has been undertaken to find out inter- and intra- lung density variations and its dosi...
متن کامل