Enzymatically and combinatorially generated array-based polyphenol metal ion sensor.
نویسندگان
چکیده
Phenolic polymers were synthesized via soybean hull peroxidase catalysis and used as metal-based sensor components in a polymer array. A sensor array for Fe(3+), Cu(2+), Co(2+), and Ni(2+) has been developed consisting of 15 phenolic homopolymers and copolymers generated from five phenolic monomers by peroxidase-catalyzed oxidative polymerization. Sensing was based on the change of intrinsic polyphenol fluorescence upon addition of a metal ion or a metal ion mixture to an aqueous suspension of a polyphenol. Importantly, the fluorescence response of copolymers differed, in some cases dramatically, from the constituent homopolymers and was dependent upon the relative ratio of monomers that comprise the polymer. This finding suggests that an extremely broad range of sensor arrays can be generated from a limited number of phenolic monomers. Using a statistical analysis, histograms constructed for the four different metal ions yielded unique fingerprints of the array response and can be used to identify specific metal ions.
منابع مشابه
An Electrochemical Sensor Based on Novel Ion Imprinted Polymeric Nanoparticles for Selective Detection of Lead Ions
In this study, the novel surface ion-imprinted polymer (IIP) particles were prepared and applied as a electrode modifier in stripping voltammetric detection of lead(II) ion. A carbon paste electrode (CPE) modified with IIP nanoparticles and multi-walled carbon nanotubes (MWCNTs) was used for accumulation of toxic lead ions. Various factors that govern on electrochemical signals including carbon...
متن کاملHighly selective and sensitive sensor based on 4,13-didecyl-1,7,10,16-tetraoxa-4,13-diazacyclooctadecane as a heterocyclic ionophore
A new polyvinyl choloride (PVC) membrane sensor for cerium (III) was prepared based on 4,13-didecyl-1,7,10,16-tetraoxa-4,13-diazacyclooctadecane (kryptofix22DD) as an ionophore. The sensor exhibites a linear concentration range of 1.0×10-6to 1.0×10-1M, with a Nernstian slope of 18.0±1.0 mV/decade, and a detection limit of 9.7×10-7M. It has a fast response time (5 s) and can be used for two mont...
متن کاملDetermination of Copper Content of Human Blood Plasma by an Ion Selective Electrode based on a New Copper-Selectophore
A new selectophore was introduced for Cu2+ ions. Spectroscopic studies showed a selectivity of a new organic compound (L) toward copper ions and several transitional metal ions. Hence, L was utilized in designing several ion selective electrodes for these cations. In practice, Cu2+ ion selective electrode behaved Nernstian (slope of 27.95±0.3 mV decade-1) over a...
متن کاملA novel sensor based on a heterocyclic ionophore for cerium (III) analysis in real samples
A new polyvinyl choloride (PVC) membrane sensor for cerium (III) was prepared based on 4,13-didecyl-1,7,10,16-tetraoxa-4,13-diazacyclooctadecane (kryptofix22DD) as an ionophore. The sensor exhibites a linear concentration range of 1.0×10-6 to 1.0×10-1 M, with a Nernstian slope of 18.0±1.0 mV/decade, and a detection limit of 9.7×10-7 M. It has a fast response time (5 s) and can be used for two m...
متن کاملA novel sensor based on a heterocyclic ionophore for cerium (III) analysis in real samples
A new polyvinyl choloride (PVC) membrane sensor for cerium(III) was prepared based on 4,13-didecyl-1,7,10,16-tetraoxa-4,13-diazacyclooctadecane (kryptofix22DD) as an ionophore. The sensorexhibites a linear concentration range of 1.0×10-6 to 1.0×10-1 M, with aNernstian slope of 18.0±1.0 mV/decade, and a detection limit of 9.7×10-7M. It has a fast response time (5 s) and can be used for two month...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Biotechnology progress
دوره 16 3 شماره
صفحات -
تاریخ انتشار 2000