LROC Model Observers for Emission Tomographic Reconstruction

نویسنده

  • Parmeshwar Khurd
چکیده

Detection and localization performance with signal location uncertainty may be summarized by Figures of Merit (FOM’s) obtained from the LROC curve. We consider model observers that may be used to compute the two LROC FOM’s: ALROC and PCL, for emission tomographic MAP reconstruction. We address the case background-known-exactly (BKE) and signal known except for location. Model observers may be used, for instance, to rapidly prototype studies that use human observers. Our FOM calculation is an ensemble method (no samples of reconstructions needed) that makes use of theoretical expressions for the mean and covariance of the reconstruction. An affine local observer computes a response at each location, and the maximum of these is used as the global observer the response needed by the LROC curve. In previous work, we had assumed the local observers to be independent and normally distributed, which allowed the use of closed form expressions to compute the FOM’s. Here, we relax the independence assumption and make the approximation that the local observer responses are jointly normal. We demonstrate a fast theoretical method to compute the mean and covariance of this joint distribution (for the signal absent and present cases) given the theoretical expressions for the reconstruction mean and covariance. We can then generate samples from this joint distribution and rapidly (since no reconstructions need be computed) compute the LROC FOM’s. We validate the results of the procedure by comparison to FOM’s obtained using a gold-standard Monte Carlo method employing a large set of reconstructed noise trials.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Model observers to predict human performance in LROC studies of SPECT reconstruction using anatomical priors [6917-26]

We investigate the use of linear model observers to predict human performance in a localization ROC (LROC) study. The task is to locate gallium-avid tumors in simulated SPECT images of a digital phantom. Our study is intended to find the optimal strength of smoothing priors incorporating various degrees of anatomical knowledge. Although humans reading the images must perform a search task, our ...

متن کامل

Impact of time-of-flight on PET tumor detection.

UNLABELLED Time-of-flight (TOF) PET uses very fast detectors to improve localization of events along coincidence lines-of-response. This information is then utilized to improve the tomographic reconstruction. This work evaluates the effect of TOF upon an observer's performance for detecting and localizing focal warm lesions in noisy PET images. METHODS An advanced anthropomorphic lesion-detec...

متن کامل

Optical tomography of the aurora and EISCAT

Tomographic reconstruction of the threedimensional auroral arc emission is used to obtain vertical and horizontal distributions of the optical auroral emission. Under the given experimental conditions with a very limited angular range and a small number of observers, algebraic reconstruction methods generally yield better results than transform techniques. Di€erent algebraic reconstruction meth...

متن کامل

Analysis of observer performance in unknown-location tasks for tomographic image reconstruction.

Our goal is to optimize regularized image reconstruction for emission tomography with respect to lesion detectability in the reconstructed images. We consider model observers whose decision variable is the maximum value of a local test statistic within a search area. Previous approaches have used simulations to evaluate the performance of such observers. We propose an alternative approach, wher...

متن کامل

Comparative evaluation of lesion detectability for 6 PET imaging platforms using a highly reproducible whole-body phantom with (22)Na lesions and localization ROC analysis.

UNLABELLED The lesion detectability performance of 6 PET imaging platforms has been compared using a highly reproducible whole-body phantom and localization receiver operating characteristic (LROC) analysis. METHODS A realistic whole-body phantom consisting of brain, thorax with lungs and liver, and pelvis with bladder was assembled and outfitted with 27 semipermanent (22)Na lesions of variou...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2004