Repeated measurements of urinary methylated/oxidative DNA lesions, acute toxicity, and mutagenicity in coke oven workers.

نویسندگان

  • Mu-Rong Chao
  • Chien-Jen Wang
  • Ming-Tsang Wu
  • Chih-Hong Pan
  • Chung-Yih Kuo
  • Hao-Jan Yang
  • Louis W Chang
  • Chiung-Wen Hu
چکیده

We conducted a repeated-measures cohort study of coke oven workers to evaluate the relationships between the traditional exposure biomarker, urinary 1-hydroxypyrene (1-OHP), and a series of biomarkers, including urinary 8-oxo-7,8-dihydro-2'-deoxyguanosine (8-oxodG), N7-methylguanine (N7-MeG), acute toxicity, and mutagenicity. A total of eight spot urine samples were collected from each high-exposed (at topside oven area) and low-exposed workers (at side oven area) during the whole working cycle, which consisted of 6 consecutive days of working followed by 2 days off. Our results showed that the high-exposed workers had significantly higher urinary levels of 1-OHP, 8-oxodG, and N7-MeG compared with the low-exposed workers. Acute toxicity and mutagenicity of urine were also found to be markedly increased in the high-exposed workers, as determined by Microtox assay and Ames test, respectively. Multivariate regressions analysis revealed that the urinary 8-oxodG, N7-MeG, or acute toxicity was significantly correlated with 1-OHP concentrations. Overall, the present study showed that exposure to coke oven emissions increased oxidatively damaged DNA products and mutagenicity of urine, and for the very first time, such exposure was also found to increase DNA methylation and urinary acute toxicity. The potential source of methylating agents in coke oven emissions warrants further investigation. Additionally, with repeated measurements, the pattern of time course for urinary 1-OHP was found to be different from those of 8-oxodG and N7-MeG, as well as acute toxicity and mutagenicity. This finding implies that the single measurement that was often conducted in occupational healthy investigations should be used with certain precautions, because single measurement may fail to provide the proper information of interest.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Urinary 1-hydroxypyrene and 8-hydroxydeoxyguanosine levels among coke-oven workers for 2 consecutive days.

OBJECTIVES This study evaluated the levels of exposure to polycyclic aromatic hydrocarbons (PAHs) and their relationship with oxidative DNA damage among Vietnamese coke-oven workers. METHODS We collected urine from 36 coke-oven workers (exposed group) at the beginning and end of the shift on 2 consecutive days. We also collected urine from 78 medical staff (control group). Information was col...

متن کامل

Association between urinary 1-hydroxypyrene and genotoxic effects in coke oven workers.

AIMS To investigate whether current occupational exposure of coke oven workers to polycyclic aromatic hydrocarbons (PAHs) results in genotoxic effects measured in peripheral blood lymphocytes and whether these biomarkers are associated with the biomarkers of exposure. METHODS Blood and urine samples were collected immediately after a shift at the end of a working week from 50 coke oven worker...

متن کامل

Assessment of potential damage to DNA in urine of coke oven workers: an assay of unscheduled DNA synthesis.

OBJECTIVES A study was conducted in coke oven workers to evaluate the biological consequences of the exposure of these workers, particularly production of potential genotoxic factors. METHODS 60 coke oven workers and 40 controls were recruited in the same iron and steel works. Exposure to polycyclic aromatic hydrocarbons (PAHs) was assessed by job and measurement of 1-hydroxypyrene (1OHP) in ...

متن کامل

Evaluation of biomarkers in plasma, blood, and urine samples from coke oven workers: significance of exposure to polycyclic aromatic hydrocarbons.

OBJECTIVE The aim was to assess the significance of two biomarkers; antibody to benzo(a)pyrene DNA adducts and concentration of hydroxyethylvaline haemoglobin adducts in samples from a well studied group of coke oven workers. As a measure of exposure we have used 1-hydroxypyrene in urine. METHODS Urine and blood samples were collected from coke oven workers and a control group. Samples from c...

متن کامل

Lymphocyte Oxidative Stress/Genotoxic Effects Are Related to Serum IgG and IgA Levels in Coke Oven Workers

We investigated oxidative stress/genotoxic effects levels, immunoglobulin levels, polycyclic aromatic hydrocarbons (PAHs) levels exposed in 126 coke oven workers and in 78 control subjects, and evaluated the association between oxidative stress/genotoxic effects levels and immunoglobulin levels. Significant differences were observed in biomarkers, including 1-hydroxypyrene levels, employment ti...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Cancer epidemiology, biomarkers & prevention : a publication of the American Association for Cancer Research, cosponsored by the American Society of Preventive Oncology

دوره 17 12  شماره 

صفحات  -

تاریخ انتشار 2008