Posterior lumbar interbody fusion (PLIF) with cages and local bone graft in the treatment of spinal stenosis.
نویسندگان
چکیده
Posterior lumbar interbody fusion (PLIF) implants are increasingly being used for 360 degrees fusion after decompression of lumbar spinal stenosis combined with degenerative instability. Both titanium and PEEK (PolyEtherEtherKetone) implants are commonly used. Assessing the clinical and radiological results as well as typical complications, such as migration of the cages, is important. In addition, questions such as which radiological parameters can be used to assess successful fusion, and whether the exclusive use of local bone graft is sufficient, are frequently debated. We prospectively evaluated 30 patients after PLIF instrumentation for degenerative lumbar spinal canal stenosis, over a course of 42 months. In all cases, titanium cages and local bone graft were used for spondylodesis. The follow-up protocol of these 30 cases included standardised clinical and radiological evaluation at 3, 6, 12 and 42 months after surgery. Overall satisfactory results were achieved. With one exception, a stable result was achieved with restoration of the intervertebral space in the anterior column. After 42 months of follow-up in most cases, a radiologically visible loss of disc space height can be demonstrated. Clinically relevant migration of the cage in the dorsal direction was detected in one case. Based on our experience, posterior lumbar interbody fusion (PLIF) can be recommended for the treatment of monosegmental and bisegmental spinal stenosis, with or without segmental instability. Postoperative evaluation is mainly based on clinical parameters since the titanium implant affects the diagnostic value of imaging studies and is responsible for artefacts. The results observed in our group of patients suggest that local autologous bone graft procured from the posterior elements after decompression is an adequate material for bone grafting in this procedure.
منابع مشابه
Spinal Decompression and Stabilization: Expandable PLIF Cages over TLIF Cages for Spinal Fusion
Study design: An in vitro biomechanical flexibility and fatigue test comparing two different lumbar interbody fusion cages using mono segmental lumbar spine specimens. Objective: To investigate and compare the stabilizing effect of a transforaminal lumbar interbody fusion (TLIF) cage against an expandable posterior lumbar interbody fusion (PLIF) cage. Method: Six intact human lumbar spine segme...
متن کاملPosterior Lumbar Interbody Fusion Using a Unilateral Single Cage and a Local Morselized Bone Graft in the Degenerative Lumbar Spine
BACKGROUND We retrospectively evaluated the clinical and radiological outcomes of posterior lumbar interbody fusion (PLIF) with using a unilateral single cage and a local morselized bone graft. METHODS Fifty three patients who underwent PLIF with a unilateral single cage filled with local morselized bone graft were enrolled in this study. The average follow-up duration was 31.1 months. The cl...
متن کاملPosterior lumbar interbody fusion using cages, combined with instrumented posterolateral fusion: a study of 75 cases.
Posterior lumbar interbody fusion (PLIF) with cages can be combined with decompression of the spinal canal and with instrumented posterolateral fusion (IPLF) with pedicle screws, through a single posterior incision. The authors wanted to assess retrospectively the clinical and radiological outcome of PLIF + IPLF performed by the senior author. Between July 1997 and December 2003, 75 patients un...
متن کاملMorphological analysis of interbody fusion following posterior lumbar interbody fusion with cages using computed tomography
Posterior lumbar interbody fusion (PLIF) using cages in conjunction with pedicle screw fixation is considered the gold standard for surgical treatment of degenerative lumbar spine disorders due to its biomechanical stability and high fusion rate. However, research regarding patterns of fusion in the interbody space during the early postoperative period is lacking.Sixty consecutive patients were...
متن کاملReport on two failed posterior lumbar interbody fusions
Despite X-ray and computed tomography signs of osseous stability after posterior lumbar interbody fusion (PLIF) procedures, the examination of two patients after 28 and 24 months respectively, revealed that the cages were wandering and consolidation had not taken place. Revision surgery was required in both cases. Introduction Fusion surgery in the region of the lumbar spine has become standard...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Acta orthopaedica Belgica
دوره 72 4 شماره
صفحات -
تاریخ انتشار 2006