SU-E-J-125: Uncertainty in Accumulated Dose to the Cochlea Due to Setup Error during External Beam Treatment of Head & Neck Cancer Patients.

نویسندگان

  • M Yan
  • D Lovelock
  • M Hunt
  • J Mechalakos
  • Y Hu
  • H Pham
  • A Jackson
چکیده

PURPOSE Treatment uncertainties are not included in modeling dose response of hearing loss. We determine uncertainty of accumulated dose to cochleas of head & neck cancer patients due to setup error during treatments of external beam IMRT. METHODS We studied 8 patients: 1 planning CT for each patient and total 40 cone beam CTs. Those patients were treated with 33 fractions. Treatments delivered 70 Gy to PTV, 50 to 60 Gy to nodal and sub-clinical disease using IMRT dose painting. Setup error was measured using 6-dimensional rigid registration between planning CT and cone beam scans obtained prior to treatment. Planning CTs were transformed and resliced to produce 'treatment CTs' according to the measured setup error matrix to simulate the cochlea position during treatment. We calculated dose delivered to cochleas at each treatment position. Treated dose to the cochlea from each fraction was accumulated on the planning CT using its registration with each 'treatment CT'. RESULTS The RMS value of set error of left cochlea is 0.48pm0.28cm, right cochlea is 0.47pm0.26cm. Mean values of left and right cochleas are ∼zero. Uncertainty in the dose to cochlea depends on each treatment plan and relative positions of the cochlea and target volumes. Average uncertainty of mean dose to cochlea is 5.0%, or 5.2cGy per fraction. CONCLUSION Patient setup error introduces uncertainty to the position of the cochlea and consequent uncertainties in accumulated dose. Our method calculates accumulated dose delivered to the same cochlea volume at different treatment positions due to setup error. We found uncertainty in cochlea doses was 5% of planned dose after 4 to 7 fractions. The largest uncertainty was 17 cGy per fraction. Our Results will be used to determine uncertainties in dose response of hearing loss in head and neck patients. NIH R01-CA129182.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Utilization of Electronic Portal Imaging Device (EPID) For Setup Verification and Determination of Setup Margin in Head and Neck Radiation Therapy

Introduction: Radiation therapy involves a multistep procedure; therefore, the error in patient set up is an inherent part of the treatment. Main purpose of this study was to determine the clinical target volume (CTV) to planning target volume (PTV) in head and neck cancer patients. Material and Methods: A total of 15 patients who had daily p...

متن کامل

Comparison of Absorbed Dose in Thyroid and Lens as Organs at Risk Between in vivo Dosimetry and 3-D Treatment Planning Calculation in Head and Neck Radiotherapy by Linac Beam

Introduction: Critical organs and structures may receive significant amounts of irradiation even if they are not the target of radiotherapy or located outside the treatment field. Although the sensitive thyroid gland and lens are not directly the targets of treatment, they can be affected by irradiation during the treatment of tumours in head and neck region. The purpose of thi...

متن کامل

Dosimetric Effects of Rotational Setup Error in Volumetric Modulated Arc Radiotherapy on Brain Tumor Patients

Introduction: This study examined the dosimetric effects based on the rotational setup error to correct patient setup errors occur during volumetric modulated arc radiotherapy (VMAT) for brain tumor patients. Material and Methods: This study included 1129 cases of cone beam computed tomography (CBCT) images obtained from 46 brain tumor patients, who experienced VMAT and used the 6DoF (degree o...

متن کامل

Evaluation of the effects of dental filling material artifacts on IMRT treatment planning in patient with nasopharyngeal cancer

Background: Presence of artifacts, caused by dental filling high-Z materials (DFM), on intensity-modulated radiation therapy (IMRT) treatment plan CT images may lead to uncertainty in head and neck calculated dose distributions. Hence, the purpose of this study was to investigate the effects of DFM on the IMRT calculated dose distribution and consequent radiobiological derived outcomes for naso...

متن کامل

Radiation-induced Hypothyroidism in Head and Neck Malignancy

Background and Objective: Hypothyroidism is a known consequence of the external beam radiotherapy to the neck encompassing the thyroid gland for over 40 years. The aim of this study was to find out the incidence of hypothyroidism in patients with head and neck cancer treated with radiotherapy, when radia...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Medical physics

دوره 39 6Part8  شماره 

صفحات  -

تاریخ انتشار 2012