Is Single-View Fluoroscopy Sufficient in Guiding Cardiac Ablation Procedures?

نویسنده

  • Pascal Fallavollita
چکیده

The CARTO XP ablation system provides real-time data on 3D, color-coded maps of the electrical activity of the heart; however, it is expensive and can only use a dedicated costly magnetic catheter per patient intervention. The purpose of our study is to shorten the duration of the radiofrequency ablation procedure and increase its efficacy by developing an affordable prototype catheter navigation system that simulates the CARTO system. To obtain 3D geometrical data from catheter locations inside the heart chamber, we acquired only single-view images using an Integris Allura fluoroscope and estimated the depth of the mapping electrode using pattern recognition techniques. Validation was performed in ideal and clinical conditions. For phantom experiment, when using a 7-French catheter, the average recovered depth error was 2.05 +/- 1.46 mm using a single image. However, when using the 8-French catheter, the average recovered depth error was 1.54 +/- 1.29 mm. In clinical experimentation, the standard error of estimate for the estimated depth was about 13.1 mm and 10.1 mm, respectively, for the posterior and lateral views. In conclusion, this paper describes our achievements and shortfalls in developing an affordable fluoroscopic navigation system to guide RF catheter ablation of cardiac arrhythmias.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Accurate assessment of patient effective radiation dose and associated detriment risk from radiofrequency catheter ablation procedures.

BACKGROUND Radiofrequency (RF) cardiac catheter ablation procedures may require extended fluoroscopic exposure resulting in elevated radiation risk. The aim of the present study was to accurately establish RF ablation radiation risk levels and to provide means for accurate patient risk estimation from studies performed in any electrophysiology laboratory. METHODS AND RESULTS Fluoroscopy requi...

متن کامل

Evaluation of Patient's Dose and Estimate of Cancer Risk in Electrophysiology Studies and Ablation in Cath Lab Center of Afshar Hospital, Yazd, Iran

Introduction: Today electrophysiology studies and ablation have been developed due to increasing arrhythmias disorder of heart. In these diagnostic – treatments methods, the use of fluoroscopy can be causes patient radiation dose, therefore evaluation of patient's absorbed dose is necessary to protection of the radiation. The aim of this study was to evaluate the absorbed dose in patients under...

متن کامل

Assessment of Maximum Entrance Skin Dose of Patients Undergoing Cardiac Interventional Procedures and Its Correlation with Other Dosimetric Parameters

Introduction: In recent years, the number of complex coronary angiography (CA) is increasing rapidly. These procedures have a significant contribution to medical exposure to the general population. Exposure of patients to high doses of x-rays could cause deterministic effects on the skin. Therefore, the assessment of radiation doses of patients is of great importance. ...

متن کامل

Catheter Ablation Without Fluoroscopy: Current Techniques And Future Direction.

Background: Catheter ablation is the treatment of choice for most forms of SVT. Traditionally, fluoroscopy has been the primary tool for visualizing catheter position. However, newer, 3-dimensional mapping technologies offer multiple options for minimizing fluoroscopy use. We review our 8 year experience of a zero-fluoroscopy approach using the Ensite system, and discuss our current techniques....

متن کامل

Shifting of puncture site in the fossa ovalis during radiofrequency catheter ablation: intracardiac echocardiography-guided transseptal left heart catheterization.

Intracardiac echocardiography (ICE) serves as an adjunct to fluoroscopy for electrophysiological procedures by identifying critical anatomic landmarks and confirming catheter-endocardial contact. In the present study, we investigated the usefulness of ICE for radiofrequency catheter ablation. ICE was utilized to guide transseptal puncture in 19 patients undergoing radiofrequency catheter ablati...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2010  شماره 

صفحات  -

تاریخ انتشار 2010