A fat suppressed adiabatic T2-preparation module for 3T

نویسندگان

  • Panki Kim
  • David Wendell
  • Eun-Ah Park
  • Hyeonjin Kim
  • Whal Lee
  • Wolfgang G Rehwald
چکیده

Background A recently developed T2-preparation module for cardiac imaging at high field is insensitive to B0 and B1 inhomogeneity, cardiac motion and flow. Obtained T2 weighted images exhibit bright fat signal that can obscure the signal of myocardium and other muscles. Therefore, a chemical selective saturation (CHESS) is usually applied for fat suppression after the T2-preparation, e.g. in coronary artery MRI. Its quality is often poor and it is unsuited for longer readout durations. In this study, we propose a new fat suppressed T2-preparation module for 3T using binomial composite RF pulses as 90° pulses to more efficiently suppress fat, maintaining robustness towards inhomogeneity, cardiac motion, and flow.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Improved fat signal suppression for coronary MRA at 3T using a water-selective adiabatic T2-Prep technique

Background In MRI, fat signal suppression is mandatory for unambiguous visualization of cardiac anatomy but remains challenging at high field. Fat saturation usually directly precedes the imaging portion of a cardiac MRI sequence. It is often used in conjunction with other magnetization preparation modules, such as T2 Preparation (or T2-Prep), to improve blood/myocardium contrast. We propose a ...

متن کامل

High-Field MR Venography using Adiabatic T2 Magnetization Preparation

Introduction Highlighting the lumen of veins while attenuating arterial signal in MRI can be of use for several clinical purposes such as guiding the placement of pacemaker leads [1] or the diagnosis of venous thrombi [2]. At a magnetic field strength of 1.5 T, coronary venography has successfully been implemented with magnetization transfer contrast (MTC) [3] prepulses. Unfortunately this appr...

متن کامل

Spectrally Selective B1 Insensitive T2 Preparation Sequence for 3T Imaging

R. Nezafat, J. A. Derbyshire, R. Ouwerkerk, M. Stuber, E. R. McVeigh Lab of Cardiac Energetics, Division of Intramural Research, NHLBI, NIH, DHHS, Bethesda, MD, United States, Biomedical Engineering, Johns Hopkins University, Baltimore, MD, United States, Radiology, Johns Hopkins University, Baltimore, MD, United States Introduction: T2 magnetization preparation (T2 Prep) and spectrally selecti...

متن کامل

Design of an adiabatic T2-preparation method optimized for cardiac motion and flow insensitivity at 3T

Background T2 contrast is important for the assessment of acute myocardial edema and coronary morphology. At 1.5T, the standard T2-prep method uses 4 composite 180° pulses (MLEV4 [1]) providing robust and uniform T2-preparation, but at 3T, increased B1 inhomogeneity causes artifacts. Decreasing inter-pulse spacing improves refocusing in the presence of motion and flow. We developed a configurab...

متن کامل

Application of continuous composite RF pulses as components of a fat-suppressed T2-preparation module for 3 Tesla - evaluation of its fat suppression efficiency in clinical cardiac patients

Background In myocardial T2-imaging, T2-preparation (T2P) is a common mechanism of creating T2-contrast to reveal pathophysiology. Because T2-contrast is often subtle, bright fat signal can hamper image analysis. Combining T2P with fat suppression (FS) is thus advantageous, but fat saturation is frequently inefficient, and fat inversion by Spectral Attenuated Inversion Recovery (SPAIR) requires...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 15  شماره 

صفحات  -

تاریخ انتشار 2013