Particle size analysis of (99m)Tc-labeled and unlabeled antimony trisulfide and rhenium sulfide colloids intended for lymphoscintigraphic application.

نویسنده

  • C Tsopelas
چکیده

UNLABELLED Colloidal particle size is an important characteristic to consider when choosing a radiopharmaceutical for mapping sentinel nodes in lymphoscintigraphy. METHODS Photon correlation spectroscopy (PCS) and transmission electron microscopy (TEM) were used to determine the particle size of antimony trisulfide and rhenium sulfide colloids, and membrane filtration (MF) was used to determine the radioactive particle size distribution of the corresponding (99m)Tc-labeled colloids. RESULTS Antimony trisulfide was found to have a diameter of 9.3 +/- 3.6 nm by TEM and 18.7 +/- 0.2 nm by PCS. Rhenium sulfide colloid was found to exist as an essentially trimodal sample with a d(v(max1)) of 40.3 nm, a d(v(max2)) of 438.6 nm, and a d(v) of 650-2200 nm, where d(v) is volume diameter. (99m)Tc-antimony trisulfide by MF showed that more than 96% of radioactive particles were smaller than 100 nm; however, (99m)Tc-rhenium sulfide showed that more than 21% were smaller than 100 nm. These radioactive colloids were used with seven different membrane compositions and found not to adsorb significantly to any of them. CONCLUSION MF was validated as a simple and reliable technique to estimate the percentage radioactive particle size distribution.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Sentinel node detection failure due to defective labeling and large particle size of Tc-99m antimony sulfide colloid

  Introduction: Many radiotracers have been used for sentinel node mapping with acceptable results. The main difference between these radiotracers is the particle size. In the current study, we reported defective labeling of Tc-99m antimony sulfide colloid which resulted in large particle size. Methods: Tc-99m-Antimony sulfide colloid was used for axillary sentinel n...

متن کامل

Sentinel node detection failure due to defective labeling and large particle size of Tc - 99 m antimony sulfide colloid

Introduction: Many radiotracers have been used for sentinel node mapping with acceptable results. The main difference between these radiotracers is the particle size. In the current study, we reported defective labeling of Tc-99m antimony sulfide colloid which resulted in large particle size. Methods: Tc-99m-Antimony sulfide colloid was used for axillary sentinel node mapping of 45 breast cance...

متن کامل

Lymphoscintigraphy is more effective using higher specific activity (99m)Tc-antimony trisulfide colloid in the rat.

Technetium-99m-antimony trisulfide colloid ((99m)Tc-ATC) was investigated with varying specific activity in the rat lymphatic system, as well as its binding to rat blood cells in vitro. Low, moderate and high doses of (99m)Tc-ATC were subdermally injected into tails of rats (n=3) and 30min later whole body lymphoscintigraphic images were acquired. (99m)Tc-ATC was incubated for 30min at 37°C wit...

متن کامل

Sentinel lymph node biopsy in melanoma patients: An experience with Tc-99m antimony sulfide colloid

  Introduction: Sentinel lymph node biopsy is the standard procedure for lymph node staging in intermediate thickness melanoma. In Iran, this procedure has not been addressed sufficiently. In this study, we report our experience in this area. Methods: Ten consecutive patients with intermediate thickness melanoma where included in our study. 1.5 mCi of Tc-99m antimony...

متن کامل

Production of 99mTc-Antimony Sulfide Colloid for lymphoscintigraphy [Persian]

Introduction: The lymphatic system provides one of the main paths for the spread (Metastasis) of cancer from one part of body to another. Hodgkin’s diseases, lymphocytic leukemia, various metastatic disease and many lymph node disorders can be assessed by lymphoscintigraphy. Radionuclide lymphoscintigraphy has been used for many years to define lymphatic drainage of melanoma. The most com...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of nuclear medicine : official publication, Society of Nuclear Medicine

دوره 42 3  شماره 

صفحات  -

تاریخ انتشار 2001