Whole cell-enzyme hybrid amperometric biosensor for direct determination of organophosphorous nerve agents with p-nitrophenyl substituent.

نویسندگان

  • Yu Lei
  • Priti Mulchandani
  • Wilfred Chen
  • Joseph Wang
  • Ashok Mulchandani
چکیده

In this paper, we reported the construction of a hybrid biosensor for direct, highly selective, sensitive, and rapid quantitative determination of organophosphate pesticides with p-nitrophenyl substituent using purified organophosphorus hydrolase (OPH) for the initial hydrolysis and Arthrobacter sp. JS443 for subsequent p-nitrophenol oxidation. The biocatalytic layer was prepared by co-immobilizing Arthrobacter sp. JS443 and OPH on a carbon paste electrode. OPH catalyzed the hydrolysis of organophosphorus pesticides with p-nitrophenyl substituent such as paraoxon and methyl parathion to release p-nitrophenol that was oxidized by the enzymatic machinery of Arthrobacter sp. JS443 to carbon dioxide through electroactive intermediates 4-nitrocatechol and 1,2,4-benzenetriol. The oxidization current of the intermediates was measured and correlated to the concentration of organophosphates. The best sensitivity and response time were obtained using a sensor constructed with 0.06 mg dry weight of cell and 965 IU of OPH operating at 400 mV applied potential (vs. Ag/AgCl reference) in 50 mM citrate-phosphate pH 7.5 buffer at room temperature. Using these conditions, the biosensor measured as low as 2.8 ppb (10 nM) of paraoxon and 5.3 ppb (20 nM) of methyl parathion without interference from phenolic compounds, carbamate pesticides, triazine herbicides, and organophosphate pesticides that do not have the p-nitrophenyl substituent. The biosensor had excellent operational life-time stability with no decrease in response for more than 40 repeated uses over a 12-h period when stored at room temperature, while its storage life was approximately 2 days when stored in the operating buffer at 4 degrees C.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Highly sensitive and selective amperometric microbial biosensor for direct determination of p-nitrophenyl-substituted organophosphate nerve agents.

We report herein a whole cell-based amperometric biosensor for highly selective, highly sensitive, direct, single-step, rapid, and cost-effective determination of organophosphate pesticides with a p-nitrophenyl substituent. The biosensor was comprised of a p-nitrophenol degrader, Pseudomonas putida JS444, genetically engineered to express organophosphorus hydrolase (OPH) on the cell surface imm...

متن کامل

Flow injection amperometric enzyme biosensor for direct determination of organophosphate nerve agents.

A flow injection amperometric biosensor for the determination of organophosphate nerve agents was developed. The biosensor incorporated an immobilized enzyme reactor that contains the enzyme organophosphorus hydrolase covalently immobilized on activated aminopropyl controlled pore glass beads and an electrochemical flow-through detector containing carbon paste working electrode, a silver/silver...

متن کامل

Biosensor for direct determination of fenitrothion and EPN using recombinant Pseudomonas putida JS444 with surface-expressed organophosphorous hydrolase. 2. Modified carbon paste electrode.

A whole cell-based amperometric biosensor for highly selective, sensitive, rapid, and cost-effective determination of the organophosphate pesticides fenitrothion and ethyl p-nitrophenol thio-benzene phosphonate (EPN) is discussed. The biosensor comprised genetically engineered p-nitrophenol (PNP)-degrading bacteria Pseudomonas putida JS444 anchoring and displaying organophosphorous hydrolase (O...

متن کامل

Amperometric microbial biosensor for direct determination of organophosphate pesticides using recombinant microorganism with surface expressed organophosphorus hydrolase.

An amperometric microbial biosensor for the direct measurement of organophosphate nerve agents is described. The sensor is based on a carbon paste electrode containing genetically engineered cells expressing organophosphorus hydrolase (OPH) on the cell surface. OPH catalyzes the hydrolysis of organophosphorus pesticides with p-nitrophenyl substituent such as paraoxon, parathion and methyl parat...

متن کامل

Direct determination of p-nitrophenyl substituent organophosphorus nerve agents using a recombinant Pseudomonas putida JS444-modified Clark oxygen electrode.

A microbial biosensor for rapid, sensitive, selective, and cost-effective determination of the total content of organophosphorus nerve agents with p-nitrophenyl substituent is reported. The biosensor consisted of genetically engineered PNP-degrader Pseudomonas putida JS444 expressing organophosphorus hydrolase (OPH) on its cell surface immobilized on a dissolved oxygen electrode. Surface-expres...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Biotechnology and bioengineering

دوره 85 7  شماره 

صفحات  -

تاریخ انتشار 2004