Atrial fibrillation ablation using a robotic catheter remote control system: initial human experience and long-term follow-up results.

نویسندگان

  • Walid Saliba
  • Vivek Y Reddy
  • Oussama Wazni
  • Jennifer E Cummings
  • J David Burkhardt
  • Michel Haissaguerre
  • Josef Kautzner
  • Petr Peichl
  • Petr Neuzil
  • Volker Schibgilla
  • Georg Noelker
  • Johannes Brachmann
  • Luigi Di Biase
  • Conor Barrett
  • Pierre Jais
  • Andrea Natale
چکیده

OBJECTIVES We present the initial clinical human experience with the use of a robotic remote navigation system (Hansen Medical, Mountain View, California), to perform left and right atrial mapping and radiofrequency ablation of atrial fibrillation (AF) and atrial flutter (AFL). BACKGROUND Catheter ablation is an established curative modality for various arrhythmias. A robotic steerable sheath system (SSS) (Hansen Medical) allows better catheter stability and greater degrees of freedom of catheter movement. METHODS A total of 40 patients (mean age 57 years) with antiarrhythmic drug (AAD)-refractory AF (23 had also concomitant documented typical AFL) were studied. Three-dimensional reconstruction of the corresponding atrial chamber anatomy was performed with the CARTO electroanatomic mapping system (Biosense Webster, Diamond Bar, California or the EnSite NavX system (St. Jude Medical, Minneapolis, Minnesota) in combination with the Artisan catheter (Hansen Medical). In patients undergoing AF ablation, 2 transseptal punctures were performed under intracardiac ultrasound (ICE) guidance, with one of the punctures being performed using SSS. Pulmonary vein antrum isolation was performed with a 3.5-mm thermocool catheter manipulated with the use of the SSS and was verified by circular mapping. Patients were followed clinically for recurrence of arrhythmia with an event transmitter and ambulatory holter monitoring. Clinical recurrence of AF/AFL was defined as AF/AFL episodes >1 min in duration. RESULTS Pulmonary vein antrum isolation was performed in 40 patients, including 23 with concomitant typical AFL ablation. All pulmonary veins, including the superior vena cava, were successfully isolated. In 23 of 40 patients, cavotricuspid ablation was also performed with bidirectional block obtained. At 1-year follow-up, 34 patients (86%) and 5 patients were free from atrial arrhythmia off AADs and on AADs, respectively. CONCLUSIONS This preliminary human experience suggests that mapping and ablation of AFL and AF using this novel robotic catheter with remote control system is feasible with similar results to conventional approach.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Atrial fibrillation ablation: state of the art.

Among several catheter-based strategies for curing atrial fibrillation (AF), 2 approaches have emerged as dominant strategies in current clinical practice: ostial segmental disconnection of all pulmonary veins (PVs) from the adjacent atrial tissue and circumferential PV ablation, first reported by our laboratory in Milan. The cure for AF by circumferential PV ablation has had a dramatic impact ...

متن کامل

Remote Robotic Navigation and Electroanatomical Mapping for Ablation of Atrial Fibrillation – Considerations for Navigation and Impact on Procedural Outcome Short Title: Remote Robotic Navigation for AF Ablation

Background: Radiofrequency current (RFC) ablation of atrial fibrillation (AF) requires high technical skills to achieve optimal catheter stability and is associated with an individually high X-ray exposure to both the patient and the operator. In order to facilitate catheter navigation and to reduce the operator’s X-ray burden remote navigation (RN) systems have been developed. Considerations f...

متن کامل

Robotic Ablation of Atrial Fibrillation

BACKGROUND Pulmonary vein isolation (PVI) is an established treatment for atrial fibrillation (AF). During PVI an electrical conduction block between pulmonary vein (PV) and left atrium (LA) is created. This conduction block prevents AF, which is triggered by irregular electric activity originating from the PV. However, transmural atrial lesions are required which can be challenging. Re-conduct...

متن کامل

Atrial Fibrillation Ablation Using Magnetic Navigation Comparison With Conventional Approach During Long-Term Follow-Up.

Atrial fibrillation (AF) ablation targeting the circumferential isolation of pulmonary veins (PVI) is an established therapeutic alternative in symptomatic AF patients resistant to anti-arrhythmic medications. The procedure is technically challenging and multiple difficulties must be overcome in order to achieve a successful outcome. The magnetic navigation system (MNS) is a remote catheter con...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the American College of Cardiology

دوره 51 25  شماره 

صفحات  -

تاریخ انتشار 2008