Magnetic beads-based chemiluminescence substrate-resolved duplex immunoassay for sequential detection of two ischemic stroke markers with two orders of concentration difference.

نویسندگان

  • Yuhao Zhang
  • Qian Xu
  • Qianwen Peng
  • Zhijuan Cao
  • Xin Wang
  • Jianzhong Lu
چکیده

Herein we have demonstrated a novel protocol to integrating two immunoassay procedures for performing a sequential dual-protein determination, based on a chemiluminescence (CL) substrate-resolved technology. We evaluated our method for the sequential determination of S100β and neuron-specific enolase (NSE) by using alkaline phosphatase (ALP) and horseradish peroxidase (HRP) as two different labels. Especially sharply different and suitable linear ranges and detection limits were successfully obtained for these two markers. Briefly, a "sandwich-type" detection strategy is employed in our design, where capture antibodies against S100β and NSE were coupled to magnetic beads. The quantification of NSE was obtained by further reacting with ALP modified antibodies and measurements by catalyzed chemiluminescence while the determination of S100β was accomplished with HRP-labeled anti-rabbit IgG. A simple CL setup was employed to perform our novel multiplexed protein assays in a single experiment. No obvious cross-reaction was observed. S100β and NSE were found to be suitably assayed in the ranges of 0.02 - 1 and 1 - 20 ng/mL, and the limits of detection were 0.005 and 0.2 ng/mL for S100β and NSE, respectively. It is straightforward to adapt this strategy to detect a spectrum of other biomarkers, which can provide important information about the early-stage diagnosis of diseases.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Flow Immunoassay Based on Sequential Injection Using Microbeads

A flow immunoassay based on a combined technique of the sequential injection with the beads injection using magnetic microbeads immobilized with antigen or antibody is described. A methodology of the present immunoassay based on chemiluminescence and electrochemical detection and its application to the determination of vitelloginin (Vg) and anionic surfactant, linear alkylbenzene sulfonate (LAS...

متن کامل

Determining the concentration of procalcitonin using a magnetic particles-based chemiluminescence assay for the clinical diagnosis of sepsis.

Our objective is to develop an assay based on magnetic particles (MPs) to determine the concentration of procalcitonin (PCT) using a chemiluminescence immunoassay (CLIA). Fluorescein isothiocyanate (FITC) and N-(aminobutyl)-N-(ethylisoluminol) (ABEI) were used to label two different anti-procalcitonin (PCT) monoclonal antibodies. The labeled antibodies, the PCT antigen, and the anti-FITC antibo...

متن کامل

Microplate magnetic chemiluminescence immunoassay for detecting urinary survivin in bladder cancer

Survivin is a tumor marker for bladder cancer; however the role of urinary survivin levels has not been fully elucidated due to the limitations of current detection methods. Based on two survivin-specific monoclonal antibodies (McAbs) already confirmed through enzyme linked immunosorbent assays, the present study aimed to establish a microplate magnetic chemiluminescence immunoassay (CLIA) for ...

متن کامل

An ultrasensitive electrogenerated chemiluminescence-based immunoassay for specific detection of Zika virus

Zika virus (ZIKV) is a globally emerging mosquito-transmitted flavivirus that can cause severe fetal abnormalities, including microcephaly. As such, highly sensitive, specific, and cost-effective diagnostic methods are urgently needed. Here, we report a novel electrogenerated chemiluminescence (ECL)-based immunoassay for ultrasensitive and specific detection of ZIKV in human biological fluids. ...

متن کامل

Chemiluminescence imaging immunoassay of multiple tumor markers for cancer screening.

A sensitive chemiluminescence (CL) imaging immunoassay method for detection of multiple tumor markers with high throughput, easy operation, and low cost was developed. The immunosensor array was prepared by covalently immobilizing capture antibodies on corresponding sensing sites on a silanized disposable glass chip. Gold nanoparticle-based bioconjugates with a high molar ratio of horseradish p...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytical sciences : the international journal of the Japan Society for Analytical Chemistry

دوره 27 7  شماره 

صفحات  -

تاریخ انتشار 2011