Planar scintigraphy with 123I/99mTc-sestamibi, 99mTc-sestamibi SPECT/CT, 11C-methionine PET/CT, or selective venous sampling before reoperation of primary hyperparathyroidism?

نویسندگان

  • Camilla Schalin-Jäntti
  • Eeva Ryhänen
  • Ilkka Heiskanen
  • Marko Seppänen
  • Johanna Arola
  • Jukka Schildt
  • Mika Väisänen
  • Lassi Nelimarkka
  • Irina Lisinen
  • Ville Aalto
  • Pirjo Nuutila
  • Matti J Välimäki
چکیده

UNLABELLED All patients with primary hyperparathyroidism should undergo localization studies before reoperation, but it is not known which method is most accurate. The purpose of this prospective study was to compare the performance of planar scintigraphy with (123)I/(99m)Tc-sestamibi, (99m)Tc-sestamibi SPECT (SPECT/CT), (11)C-methionine PET/CT, and selective venous sampling (SVS) in persistent primary hyperparathyroidism. METHODS Twenty-one patients referred for reoperation of persistent hyperparathyroidism were included and investigated with (123)I/(99m)Tc-sestamibi, SPECT/CT (n = 19), (11)C-methionine PET/CT, and SVS (n = 18) before reoperation. All patients had been operated on 1-2 times previously because of hyperparathyroidism. The results of the localization studies were compared with operative findings, histology, and biochemical cure. RESULTS Eighteen (86%) of 21 patients were biochemically cured. Nineteen parathyroid glands (9 adenomas, 1 atypical adenoma, and 9 hyperplastic glands) were removed from 17 patients, and 1 patient who was biochemically cured had an unclear histology result. The accuracy for localizing a pathologic parathyroid gland to the correct side of the neck was 59% (95% confidence interval [CI], 36%-79%) for (123)I/(99m)Tc-sestamibi, 19% (95% CI, 5%-42%) for SPECT/CT, 65% (95% CI, 43%-84%) for (11)C-methionine PET/CT, and 40% (95% CI, 19%-65%) for SVS (P < 0.01 for (123)I/(99m)Tc-sestamibi vs. SPECT/CT). The corresponding accuracy for the correct quadrant or more specific site was 48% (95% CI, 27%-69%) for (123)I/(99m)Tc-sestamibi, 14% (95% CI, 3%-36%) for SPECT/CT, 61% (95% CI, 39%-80%) for (11)C-methionine PET/CT, and 25% (95% CI, 9%-49%) for SVS (P < 0.02 for (123)I/(99m)Tc-sestamibi vs. SPECT/CT). In the 3 patients not cured, preoperative (123)I/(99m)Tc-sestamibi and SPECT/CT remained negative, SVS was false predictive in all, and (11)C-methionine PET/CT in 1. (11)C-methionine PET/CT accurately revealed the pathologic gland in 4 of 8 (50%) patients with a negative (123)I/(99m)Tc-sestamibi scan result, all of whom were biochemically cured after reoperation. CONCLUSION Planar scintigraphy with (123)I/(99m)Tc-sestamibi performs well in complicated primary hyperparathyroidism and is recommended as first-line imaging before reoperation. (11)C-methionine PET/CT provides valuable additional information if (123)I/(99m)Tc-sestamibi scan results remain negative. (99m)Tc-sestamibi SPECT/CT and SVS provide no additional information, compared with the combined results of (123)I/(99m)Tc-sestamibi and (11)C-methionine PET/CT imaging.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

99mTc-Sestamibi/123I Subtraction SPECT/CT in Parathyroid Scintigraphy: Is Additional Pinhole Imaging Useful?

Objectives This retrospective study evaluated whether the use of additional anterior 99mTc-sestamibi/123I pinhole imaging improves the outcome of 99mTc-sestamibi/123I subtraction SPECT/CT in parathyroid scintigraphy (PS). Materials and Methods PS using simultaneous dual-isotope subtraction methods and an acquisition protocol combining SPECT/CT and planar pinhole imaging was performed for 175 ...

متن کامل

Preoperative ⁹⁹mTc-sestamibi scintigraphy in patients with primary hyperparathyroidism and concomitant nodular goiter: comparison of SPECT-CT, SPECT, and planar imaging.

BACKGROUND Investigations using a hybrid single photon emission computed tomography/computed tomography (SPECT-CT) scanning technique have been carried out in limited studies and have shown mixed results. However, the assessment of this technique for the detection of parathyroid adenoma in patients with a nodular goiter was performed in only one study with a small sample size. The aim of this p...

متن کامل

Utility of 99mTc-Sestamibi SPECT/CT in the Early Localization of Metastatic Parathyroid Carcinoma

Parathyroid carcinoma is very rare, with only a few documented cases. Hence, metastatic lesions are infrequently documented on scintigraphic imaging. We present a case of a 63-year-old female presenting with elevated serum levels of ionized calcium and parathyroid hormone (PTH) who was referred to our department for a parathyroid scan with SPECT/ CT. Parathyroid scintigraphy showed a focus of i...

متن کامل

The Significance of 18F-Fluorocholine-PET/CT as Localizing Imaging Technique in Patients with Primary Hyperparathyroidism and Negative Conventional Imaging

Objective The essential prerequisite for focused parathyroidectomy in patients with primary hyperparathyroidism (pHPT) is proper localization of all autonomic tissue. Sensitivity of conventional imaging modalities (ultrasound, 99mTc-sestamibi scintigraphy/SPECT/CT) is influenced by different factors (i.e., size/weight and position of autonomic tissue) and decreases in the presence of a multinod...

متن کامل

99mTc-MIBI SPECT/CT imaging contribution in the diagnosis of patients with hyperparathyroidism

Introduction: Hyperparathyroidism is presented with increased parathyroid hormone (PTH) secretion due to hyperfunctioning of one or more of the four parathyroid glands. Primary hyperparathyroidism (p-HPT) can be due to parathyroid adenoma, hyperplasia or carcinoma of the parathyroid gland. Secondary hyperparathyroidism (s-HPT) is usually a response to hypocalcaemia and consecut...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of nuclear medicine : official publication, Society of Nuclear Medicine

دوره 54 5  شماره 

صفحات  -

تاریخ انتشار 2013